EasyManua.ls Logo

Cressi RAFFAELLO - GAGE MODE (Depth Gauge and Timer)

Cressi RAFFAELLO
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
34
English
NOTE:ToavoidtheriskofdecompressionsicknessinFREEdives,noother
divemodesarepermittedforthe24hoursthatfollow.
GAGE MODE (depth gauge and timer).
In addition to the AIR, NITROX, and FREE modes, the computer also features a
fourthprogramcalledGAGE(depthgaugeandtimer)thatcanbeusedbythose
whoengagein"technical"dives. In this case,the instrument provides just the
basic dive parameters, i.e. depth, dive time, average depth, and temperature. It
doesnotcalculatetissuesaturationanddesaturation,whichmustbeprogrammed
andcalculatedusingspecialsoftwareand/ortables.Cressistronglyrecommends
thatallrecreationaldiving activities be conducted withintheguidelinesforno-
decompression diving and to a maximum depth of 132 ft./40 m.Exceeding
theseperimetersdramaticallyincreasesthelikelihoodofdecompressionsickness.
WhensettoGAGEmode,duringadivewithinthenodecompressionlimits,the
displaywillshowthefollowinginformation:
•Maximumdepthreached
•Divetime(minutes)
•Currentdepth
•Divetime(seconds)
•Averagedepth(A.)
•Temperature
Toshowthecurrenttime,Short
Short \ NEXT (ONE STEP)
Long (3 Sec.) \ RETURN
Long (1 Sec.) \ ENTER \ ESC
press the button.
WARNING: The DONATELLO/MICHELANGELO/RAFFAELLO computer
is designed for recreational diving only. It is not intended for commercial
or professional use, requiring longer dive times and greater depths. Diving
beyondtheparametersofrecreationaldivingdramaticallyincreasestheriskof
decompressionsickness.
DANGER: Cressi discourages diving with gaseous mixtures other
than air without proper training. This is because the so-called
"technical" dives can expose the diver to different risks than
recreational dives, which can include serious physical harm and in
extreme cases even death.
WARNING:After a dive in GAGE mode, the instrument will not calculate
saturationanddesaturationforthefollowing48hours.
DANGER: Should you decide to reset the instrument by accessing
the system mode, the nitrogen memory will be deleted. Therefore,
the instrument will not be able to calculate the following dive.
Before using this function, wait for at least 48 hours after the most
recent diving activity.
WhentheGagefunctionisactive,theGAGEiconwillappear.
NOTE:TheDONATELLO/MICHELANGELO/RAFFAELLOissettoMODESET
(MODE-S)AIRatthefactory.
MAX
DEPTH
TEMP.DEPTH AVG
DEPTH
DIVE
TIME (SEC.)
DIVE
TIME
(MIN.)