EasyManua.ls Logo

Crestron CHV-TSTAT - Heat Pump Connections (Single & Two-Stage)

Crestron CHV-TSTAT
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Crestron CHV-TSTAT and CHV-THSTAT Thermostats
Heat Pump Connections (Single & Two-Stage)
Aux Heat connected to W/W1 – RH and RC jumped together
TOP
HUM
RHU
RSR
RSR
RS1
RS2
24(C)
24(R)
24V
Y
Z
G
NETWORK
RH
RC
G
Y/Y1
Y2
O
B
W/W1
W2
Backplate
Jumper
From RH
to RC
Integrated
Control Unit
C
R
Y
G
O
Aux
Y2
(2
nd
Stage)
3
4
P4
Jumper on
P4 pins 3 & 4
Thermostat Circuit Board
CRESTRON ELECTRONICS
P1
P3
P6
P5
P4
1
2
3
4
C
R GYY2O Aux
NOTE: For wiring details, refer to the general Heat Pump schematic on the
following page.