EasyManua.ls Logo

Crowcon Clip O2 - Self Test and Bump Test; Self Test; Bump Test

Crowcon Clip O2
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
Clip SGD
7. Self Test and Bump Test
7.1 Self Test
TheClipSGDprovidesaSelfTestfunction.
ThedefaultintervaloftheSelfTestreminderis20hrs.
UsetheIRLinkorDockingStationtoconguretheintervalbetween1hrand20hrs,orsetto
“off”.
WhentheconguredSelfTestisdue,“STS”willashonthescreen(themessagewill
continuetoashuntiltheuserperformsasuccessfulSelfTest).
MAX
LEL
PPM
VOL
%
%
MN
I
ALARM
1
V
M
D
T
X
2
PPM
1
PPM
2
• PressthebuttontoinitiatetheSelfTestfunction.
Thedevicewillperformaselftestbyoperatingthebuzzer,LED’s,vibratorandLCD.Itwillalso
showtheconguredlowandhighalarmsetpointsonthedisplay.
Afterthetestiscompleted,“END”willbedisplayedonthescreen.(Theuserisrequiredto
checkthattheitemsoperatedintheselftest,performedasexpected).
7.2 Bump Test
ThedevicecanbeconguredtoprovideanonscreenBumpTestreminder.
ThedefaultsettingfortheBumpTestreminderis“off”,noBumpTestreminderwillbe
displayed.
IfaBumpTestreminderintervalisrequireditcanbeconguredusingtheIRLinkorDocking
Station.Theintervalcanbeconguredfrom1dayto365days.
WhenconguredandaBumpTestisdue,the“bts”messagebedisplayedandwillashon
thescreen.