EasyManua.ls Logo

Crown Com-Tech CT-1600 User Manual

Crown Com-Tech CT-1600
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
K80636-2
3/95
®
Commercial
Audio
LL 32521C
®
Fire Protective
Signaling
S5206
®
Commercial
Audio
E106377
120 VAC
North
American
Units:
Approved for
THX Theatre
Systems
(CT-400 & 800)
POWER
ODEP
IOC
SPI
ENABLE
CH1 CH2
OFF
POWER
ODEP
IOC
SPI
ENABLE
CH1 CH2
OFF
POWER
ODEP
IOC
SPI
ENABLE
CH1 CH2
OFF
POWER
ODEP
IOC
SPI
ENABLE
CH1 CH2
OFF
Copyright ©1995 by Crown International, Inc., P.O. Box 1000, Elkhart, Indiana 46515-1000 U.S.A.
Telephone: 219-294-8000. Com-Tech amplifiers are produced by the Professional Audio Division of
Crown International, Inc. Trademark Notice:
SmartAmp
,
MPX-6
,
SMX-6
,
AMB-5
and
Grounded
bridge
are trademarks and
Amcron
,
®
Crown
,
®
Techron
,
®
Com-Tech
,
®
IOC
,
®
ODEP
,
®
IQ System
,
®
P.I.P.
®
and
TEF
®
are registered trademarks of Crown International, Inc. Other trademarks are the property of
their respective owners.
Models:
Com-Tech 200, 400, 800 & 1600
Some models may be exported under the name
Amcron
.
®
COM-TECH
®

Table of Contents

Other manuals for Crown Com-Tech CT-1600

Question and Answer IconNeed help?

Do you have a question about the Crown Com-Tech CT-1600 and is the answer not in the manual?

Crown Com-Tech CT-1600 Specifications

General IconGeneral
Channels2
Frequency Response20Hz - 20kHz
THD<0.05%
Signal to Noise Ratio>100 dB
Input Sensitivity1.4V
Power Output1600W
Total Harmonic Distortion<0.05%
Input Impedance20k ohms balanced, 10k ohms unbalanced
Dimensions19" x 3.5" x 16"

Summary

Warranty Information

Worldwide Warranty

Summary of Crown warranty terms for global coverage.

North America Warranty

Summary of Crown warranty terms for North American coverage.

Fire Protective Signaling

Fire Protective Signaling Systems

UL listing and requirements for fire alarm systems.

Welcome and Introduction

Unpacking and Inspection

Procedures for unpacking and checking for shipping damage.

Amplifier Features

Key technological advancements and benefits of the amplifier.

Facilities Overview

Front Panel Facilities

Description of indicators, switches, and connectors on the front panel.

Rear Panel Controls and Connections

Description of rear panel switches, inputs, and outputs.

Installation Procedures

Mounting and Rack Installation

Guidelines for physically installing the amplifier in racks or stacks.

Cooling and Airflow Management

Importance of ventilation and methods for optimal cooling.

Wiring and Input/Output Connections

Guidance on connecting inputs, outputs, and various wiring configurations.

Input Connection Details

Details on connecting input signals and solving input problems.

Output Connection Procedures

Details on connecting output loads and using good connectors.

Additional Load Protection

Methods for protecting loudspeakers from power issues.

AC Mains Power Connection

Information on power requirements, cords, and outlets.

Operation and Controls

Operating Precautions

Essential safety and operational advice for using the amplifier.

Front Panel Indicators

Explanation of ODEP, IOC, SPI, and Enable indicator states.

Protection Systems Overview

Description of ODEP, standby, and circuit breaker protection features.

Amplifier Controls and Adjustments

Details on using level controls, sensitivity switches, and filter cleaning.

Technical Information

Amplifier Overview and Technology

Introduction to Com-Tech technology and design principles.

Circuit Theory and Operation Modes

Explanation of dual, bridge-mono, and parallel-mono circuit operation.

Specifications

Performance Characteristics

Details on frequency response, distortion, damping factor, etc.

Power Output Ratings

Guaranteed minimum power output under various conditions.

Control and Input/Output Specs

Specs for controls, indicators, input impedance, and sensitivity.

Construction and Physical Data

Information on build, dimensions, weight, and cooling design.

Power Matrices

Minimum Guaranteed Power

Detailed power output tables for Com-Tech 200.

Com-Tech 400 Minimum Power Matrix

Detailed power output tables for Com-Tech 400.

Com-Tech 800 Minimum Power Matrix

Detailed power output tables for Com-Tech 800.

Com-Tech 1600 Minimum Power Matrix

Detailed power output tables for Com-Tech 1600.

Maximum Power Specifications

Tables showing maximum power output under burst conditions.

Com-Tech 200 Maximum Power Matrix

Maximum power output tables for CT200 under burst.

Com-Tech 400 Maximum Power Matrix

Maximum power output tables for CT400 under burst.

Com-Tech 800 Maximum Power Matrix

Maximum power output tables for CT800 under burst.

Com-Tech 1600 Maximum Power Matrix

Maximum power output tables for CT1600 under burst.

Performance Graphs

Frequency Response and Damping Factor

Graphs showing amplifier frequency response and damping factor.

Phase Response and Crosstalk

Graphs detailing phase response and channel crosstalk.

AC Power Draw and Thermal Dissipation

Accessories

P.I.P. Modules Overview

Introduction to Programmable Input Processor modules and their functions.

Cooling Fan Option

Details and installation for the optional cooling fan kit.

Constant Voltage Computer

Information on the audio application slide rule.

Fire Protective Signaling Requirements

Service and Support

Worldwide Service Information

Procedures for obtaining service globally.

North American Service Options

Procedures for obtaining service within North America.

Related product manuals