EasyManua.ls Logo

Crown Contractor Series User Manual

Crown Contractor Series
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
MIN
ARY
PRELIMINARY
MIN
ARY
MINARY
MINA
PRELIM
INA
MIN
ARY
PRELIMINARY
PRELIMINARY
PRELI
MIN
LIM
INARY
LIMIN
PREL
IM
PREL
IM
PRELIMINAR Y
PRELI
MIN
130808-1
5/00
Models:
CH1, CH2, CH4
CL1, CL2, CL4
Some models may be exported under the name
Amcron
.
®
ConCon
ConCon
Con
trtr
trtr
tr
actor Seriesactor Series
actor Seriesactor Series
actor Series
Note on Preliminary Status: Crown continues to stand behind its products as guaranteed to meet or exceed
published specifications. However, at the time of this manual’s publication, not all of the CH and CL models
were in production. Guaranteed specifications for all CH and CL models will be issued at the time of product
release.
© 2000 by Crown International, Inc., P.O. Box 1000, Elkhart, IN 46515-1000 U.S.A. Telephone: 219-294-8000.
Fax: 219-294-8329. Trademark Notice:
Amcron
®
and
Crown
®
are registered trademarks of Crown
International, Inc. Other trademarks are the property of their respective owners.
Obtaining Other Language Versions:
To obtain information in another language about the use of this product, please contact your local Crown Distribu-
tor. If you need assistance locating your local distributor, please contact Crown International at 219-294-8200.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Crown Contractor Series and is the answer not in the manual?

Crown Contractor Series Specifications

General IconGeneral
BrandCrown
CategoryAmplifier
Channels2
SeriesContractor
Signal to Noise Ratio>100dB
Power OutputSee 8 Ohm Stereo, 4 Ohm Stereo, 8 Ohm Bridged-Mono
Frequency Response20Hz - 20kHz
Input Impedance20k Ohms

Summary

Important Safety Instructions

Apparatus Proximity to Water

Avoid using the apparatus near water sources to prevent damage or shock.

Cleaning Instructions

Clean the apparatus exclusively with a dry cloth.

Ventilation Opening Precautions

Ensure ventilation openings are not blocked during installation and operation.

Heat Source Installation

Avoid installing the apparatus near heat-producing sources like radiators or stoves.

Plug Safety Features

Do not alter or defeat the safety purpose of polarized or grounding-type plugs.

Power Cord Protection

Protect the power cord from being walked on or pinched, especially at connection points.

Approved Accessories

Use only manufacturer-specified attachments and accessories for safety and performance.

Mounting and Cart Usage

Use only manufacturer-specified carts, stands, brackets, or tables; exercise caution when moving.

Unplugging During Storms/Idle Periods

Unplug the apparatus during lightning storms or extended periods of non-use.

Qualified Servicing

All servicing must be performed by qualified service personnel to ensure safety.

Moisture and Fire Hazard

Do not expose the apparatus to rain or moisture to reduce fire and electric shock risk.

Worldwide and North America Warranty

Warranty Summary

Overview of the three-year, no-fault, full warranty coverage for Crown products.

Warranty Exclusions

Details items and conditions not covered by the Crown product warranty.

Obtaining Warranty Service

Procedure for notifying Crown and obtaining warranty service for defective products.

Damage Disclaimers

Disclaimer regarding consequential and incidental damages resulting from product defects.

Welcome and Product Overview

Unpacking and Inspection

Instructions for unpacking, inspecting for transit damage, and saving packing materials.

Key Product Features

Highlights the designed features for fixed installation, including impedance compatibility and SST system.

Controls, Indicators, and Connectors

Front Panel Controls and Indicators

Describes the front panel layout including power, signal, clip, and fault indicators.

Back Panel Controls and Connectors

Details rear panel connections and controls for CH, CL series amplifiers.

Installation Procedures

Amplifier Mounting Guidelines

Provides instructions for rack mounting Contractor Series amplifiers and considerations for airflow and support.

Wiring Configuration

Explains wiring options based on output mode (4/8 ohm, 70V/100V) and stereo/bridge modes.

Operating the Amplifier

Pre-Operation Precautions

Essential safety and operational precautions to follow before and during amplifier use.

Startup Procedure

Step-by-step guide for safely turning on and setting up the amplifier for initial use.

Front Panel Indicators

Explanation of the function and meaning of the amplifier's front panel indicators (Power, Fault, Clip, Signal).

Additional Controls and Advanced Features

Additional Amplifier Controls

Details on the Enable switch, Precision Detented Level Controls, Stereo/Bridge switch, and Fault Jack.

BCA (Balanced Current Amplifier) Technology

Explains the benefits of BCA technology for high-power audio amplification.

Switching Power Supply with PFC

Describes the PFC boost stage for global AC compatibility and power efficiency.

Crown SST Modules

Overview of SST modules for tailoring amplifier functionality and adding future technology.

Fault Monitoring and Constant Voltage Computer

Details on the Fault (RJ11) jack for remote status monitoring and the Constant Voltage Computer feature.

Principles of Operation

CH1, CH2, CL1 and CL2 Signal Path

Describes the audio signal flow through the amplifier stages for CH/CL models.

CH4 and CL4 Signal Path

Details the audio signal path for CH4 and CL4 models, including filters and error amp.

Product Specifications

Load Impedance and Voltage Gain

Specifies safe load impedances and voltage gain values for various models and modes.

AC Line Requirements and Current Draw

Details AC voltage requirements, current draw, and connector type for different models.

Performance Metrics

Covers frequency response, phase response, signal-to-noise ratio, distortion, and damping factor.

AC Power Draw and Thermal Dissipation

Power Draw and Thermal Calculations

Explains equations for calculating AC power draw, current, and thermal dissipation under various conditions.

Installation and Wiring Assistance

Cooling Requirements

Discusses cooling considerations for Contractor Series amplifiers, including rack mounting and airflow.

Input Wiring Best Practices

Provides guidelines for balanced and unbalanced input wiring, including problem-solving for input signals.

Output Mode Configurations

Details 4/8 ohm and 70V/100V operation modes, including their applications and requirements.

Output Wiring and Cable Selection

Covers output wiring, solving output problems, and selecting appropriate speaker cables.

Solving Output Problems

Addresses issues like high-frequency oscillations and inductive loads, and protection methods.

Additional Load Protection

Explains using fuses and outboard limiters to protect loudspeakers from thermal and transient damage.

Fault Circuit Wiring

Explains how to set up a circuit to light an LED when a fault status occurs.

System Applications Examples

Restaurant System Example

Illustrates a restaurant audio system configuration using CH1, CL2, and CL4 amplifiers.

House of Worship System Example

Shows a house of worship audio system setup utilizing CH1, CL2, and CL4 amplifiers.

Service and Support Information

Worldwide and North American Service

Details how to obtain service globally and within North America, including factory service.

Profit Protection Plan and Customer Service

Information on the advance-replacement plan and how to contact Crown Audio Customer Service.

Related product manuals