EasyManua.ls Logo

Crown Com-Tech CT-1600 - Specifications; Performance Characteristics; Power Output Ratings

Crown Com-Tech CT-1600
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 29
Com-Tech 200/400/800/1600 Power Amplifiers
®
Commercial
Audio
LL 32521C
®
Fire Protective
Signaling
S5206
®
Commercial
Audio
E106377
120 VAC
North
American
Units:
Approved for
THX Theatre
Systems
(CT-400 & 800)
6 Specifications
The following specifications apply to all models in Dual mode
with 8 ohm loads and an input sensitivity of 26 dB unless
otherwise specified. In Fire Protective Signaling Applica-
tions, the specifications in Section 9 supersede several of
the specifications that follow.
Standard 1 kHz Power: This term refers to maximum average
power in watts at 1 kHz with 0.1% THD.
Full Bandwidth Power: This term refers to maximum average
power in watts from 20 Hz to 20 kHz with 0.1% THD.
120 VAC, 60 Hz Units: These North American units have
dedicated transformers for 120 VAC, 60 Hz power mains.
100/120 VAC Units: These units have two-tap transformers
that accept a 50 or 60 Hz AC line, and can be configured for
100 or 120 VAC mains.
220/240 VAC Units: These units have two-tap transformers
that accept a 50 or 60 Hz AC line, and can be configured for
220 or 240 VAC mains.
Performance
Frequency Response: ±0.1 dB from 20 Hz to 20 kHz at
1 watt (see Figure 6.9).
Phase Response: ±10 degrees from 10 Hz to 20 kHz
at 1 watt (see Figure 6.12).
Hum and Noise: A-weighted, 105 dB below full band-
width power; No weighting, 100 dB below full band-
width power.
Total Harmonic Distortion (THD): Less than 0.05% at
full bandwidth power from 20 Hz to 1 kHz increasing
linearly to less than 0.1% at 20 kHz.
Intermodulation Distortion (IMD): (60 Hz and 7 kHz
4:1) Less than 0.05% from less than 166 milliwatts to
full bandwidth power.
Damping Factor: Greater than 1000 from 10 Hz to
400 Hz (see Figure 6.10).
Crosstalk: See Figure 6.13.
Common Mode Rejection Ratio (CMRR): Better than
70 dB.
Slew Rate: Greater than 17 volts per microsecond.
Voltage Gain: (At the maximum level setting) 20:1 ±3%
or 26 dB ±0.25 dB. 90:1 ±12% or 39 dB ±1 dB with the
input sensitivity set to 0.775 volts for 70 volt output. The
following voltage gain specifications are for units with
the input sensitivity set to 0.775 volts for 8/4 ohm output:
Com-Tech 200
: 38:1 ±12% or 32 dB ±1 dB.
Com-Tech 400
: 55:1 ±12% or 35 dB ±1 dB.
Com-Tech 800
: 64:1 ±12% or 36 dB ±1 dB.
Com-Tech 1600
: 85:1 ±12% or 39 dB ±1 dB.
Power
Output Power:
The following are guaranteed minimums
for standard 1 kHz power from 120 VAC, 60 Hz North
American units. For more information or specs on inter-
national units, see the power matrices that follow.
Com-Tech 200
Dual mode (with both channels driven):
150 watts into 4 ohms.
110 watts into 8 ohms.
110 watts with 70 volt output.
Bridge-Mono mode:
300 watts into 8 ohms.
220 watts into 16 ohms.
205 watts in 70 volt mode (140 volt output).
Parallel-Mono mode:
295 watts into 2 ohms.
215 watts into 4 ohms.
210 watts with 70 volt output.
Com-Tech 400
Dual mode (with both channels driven):
240 watts into 4 ohms.
220 watts into 8 ohms.
225 watts with 70 volt output.
Bridge-Mono mode:
475 watts into 8 ohms.
450 watts into 16 ohms.
455 watts in 70 volt mode (140 volt output).

Table of Contents

Other manuals for Crown Com-Tech CT-1600

Related product manuals