Parameters table
*
Parameter 01 allows you to change the deviation degree interval from the requested temperature so that the heat pump starts again.
Example : If the value of parameter 01 is 3°C, after reaching the required temperature (eg 27°C), the heat pump will restart when the pool
temperature drops to 24°C (27 - 3).
22
N° Description Adjustment range Factory setting Remarks
01*
Adjustment of temperature difference before restart 1~18°C 1°C Adjustable
02
Reserved - Do not adjust Reserved
03
Reserved - Do not adjust Reserved
04
Adjusting the cooling temperature 8~28°C 27°C Adjustable
05
Adjusting the heating temperature 15~40°C 27°C Adjustable
06
Reserved - Do not adjust Reserved
07
Reserved - Do not adjust Reserved
08
Reserved - Do not adjust Reserved
09
Setting the compensation coefficient of the temperature water inlet -5~15°C0°CAdjustable
10
Reserved - Do not adjust Reserved
11 Auto-activation time before de-icing commences 20~90 min 45 min Adjustable
12
De-icing activation temperature -15~1°C -3°C Adjustable
13
Maximum de-icing duration 5~20 min 8 min Adjustable
14
De-icing deactivation temperature 1~40°C 20°C Adjustable
15
Reserved - Do not adjust Reserved
16
Reserved - Do not adjust Reserved
17
Expansive valve action period 20~90s 45s Adjustable
18
Reserved - Do not adjust Reserved
19
Reserved - Do not adjust Reserved
20
Reserved - Do not adjust Reserved
21
The mini opening for the electrical expansive valve 50~150 80 Adjustable
22
Reserved - Do not adjust Reserved
23
Reserved - Do not adjust Reserved
24
Reserved - Do not adjust Reserved
25
Reserved - Do not adjust Reserved
26
Reserved - Do not adjust Reserved
27
Reserved - Do not adjust Reserved
28**
Filtration pump servo-control mode 0 ~ 1
0
Adjustable
29
Max water outlet temp set in heating mode 25~40°C 40 Adjustable