Safety & Certications 31
XP2i Operation Manual
Safety Instructions for Hazardous Locations – ENGLISH (English)
Do not use the RS-232 connector in a hazardous location.
Replace batteries in non-hazardous locations, with approved batteries, only.
It is the users responsibility to understand the proper application of this product in potentially explosive atmospheres.
The equipment shall not be installed in a location where the external conditions are conducive to the buildup of electrostatic charge.
The equipment shall be installed in such a way, that even in the event of rare incidents, ignition sources due to impact and friction sparks shall be avoided.
X
Approved Batteries – ENGLISH (English)
The XP2i is Intrinsically Safe only if powered by one of the following battery types:
Approved Battery Type Ta= Marking
Rayovac Max Plus 815
-20 to 50° C Ex ia IIC T4 Ga
Energizer E91
Energizer EN91
-20 to 50° C Ex ia IIC T3 Ga
Duracell MN1500
Replace batteries with approved type in non-hazardous locations only
Many other battery types and models have been tested but failed to meet the requirements for Intrinsic Safety
do not assume other models are equivalent.
Energizer is manufactured by Energizer Holdings, Inc., and the Eveready Battery Company, Inc.
Instrucciones De Seguridad Para Zonas Peligrosas – ESPAÑOL (Spanish)
No use el conector RS-232 en zona clasicada.
Cambie las pilas en zona no clasicada, solo con pilas aprobadas.
Es responsabilidad del usario comprender la aplicación de este producto en atmósferas potencialmente explosivas.
El equipo no se debe instalar en un lugar donde las condiciones externas son favorables a la acumulación de cargas electrostáticas.
El equipo se deberá instalar de tal modo que, incluso en el caso de un accidente, las fuentes de ignición debido a chispas por fricción o impactos sean evitadas.
X
Pilas Aprobadas – ESPAÑOL (Spanish)
El XP2i solo es intrínsecamente seguro si se alimenta con uno de los siguientes tipos de pilas:
Approved Battery Type Ta= Marking
Rayovac Max Plus 815
-20 to 50° C Ex ia IIC T4 Ga
Energizer E91
Energizer EN91
-20 to 50° C Ex ia IIC T3 Ga
Duracell MN1500
Replace batteries with approved type in non-hazardous locations only
Se han probado muchos otros tipos de baterías pero han fallado el cumplimiento de los requisitos para la seguridad intrínseca
No asuma que otros modelos son equiva-
lentes.
Energizer está fabricado por Energizer Holdings, Inc., y por Eveready Battery Company, Inc.