EasyManua.ls Logo

Crystal XP2i User Manual

Crystal XP2i
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
XP2i
Operation Manual
for XP2i Digital Test Gauge (Standard and Dual-Display(DD))
Question and Answer IconNeed help?

Do you have a question about the Crystal XP2i and is the answer not in the manual?

Crystal XP2i Specifications

General IconGeneral
BrandCrystal
ModelXP2i
CategoryTest Equipment
LanguageEnglish

Summary

Overview

Introduction

Provides an overview of the XP2i Digital Test Gauge and its features.

Operating Instructions

Functions

Units Button

Explains how to cycle through available pressure measurement units.

Peak Button

Describes how to display peak, valley, PSV, and average pressure readings.

Resetting Peak Values

How to clear recorded peak high and peak low pressure values.

Zero Function

How to zero the gauge and clear the zero value.

Tare Function

How to subtract a constant value from the true pressure reading.

Rate Function

How to measure and display pressure change per minute.

Differential Mode

How to display pressure difference between two gauges.

Automatic Shut-off

Explains the auto shut-off feature and how to disable it.

Backlight Control

How to control the display backlight brightness and duration.

Measuring Vacuum

How to measure vacuum and limitations for continuous use.

Water Density Settings

How to check and change water density for inches of water unit.

Overpressure Conditions

What happens when the gauge exceeds its rated pressure range.

PSVtest Mode

Mode for PSV, PRV, and Rupture Disc testing.

Low Battery Indication

How the battery level is indicated.

Battery Replacement

Instructions for replacing the gauge batteries.

Reset Procedure

How to reset the XP2i gauge.

Communications and Programming

Overview of remote control via command language.

Data Logging with DataLoggerXP

What is DataLoggerXP?

Introduces the optional data logging mode and its capabilities.

DataLoggerXP Terminology

Defines key terms used in DataLoggerXP software and operation.

Typical Usage

Outlines a common workflow for using DataLoggerXP.

Installing the Software

Instructions for installing the DataLoggerXP software.

Authorizing a Gauge

How to authorize the gauge for full data point recording capability.

Software Operation

Describes the functional areas of the DataLoggerXP application.

Setting the Options

How to configure software options like serial port detection.

Connecting to the Gauge

Steps to connect the XP2i gauge to the computer.

Password Protection

How to set and manage password protection for data logging.

Data Logging Parameters

How to set logging interval and logging type.

Logging Interval

Controls the frequency of measurements during data logging.

Logging Type

Defines how data is recorded (Actual, Average, etc.).

Data Management

How to manage downloaded data.

Downloading Data

Steps to download recorded data from the gauge.

Viewing Data Runs

How to view recorded data runs in the Data View dialog.

Saving Data Runs

How to save recorded data runs to a file.

Saving in Excel Format

How to save data in Excel workbook or text file format.

Clearing All Data Runs

How to erase all logged data from the gauge's memory.

XP2i DataLoggerXP Gauge Operation

Maximum Number of Readings

Information on the maximum data points that can be recorded.

Recording Pressure

Step-by-step guide to starting and stopping data recording.

Keypad Usage

Explains button combinations for data logging control.

Setting Logging Parameters

How to set logging mode and interval using the keypad.

Setting the Logging Interval

Detailed steps for setting the logging interval via keypad.

Units Button Usage

How the units button displays logging state and controls runs.

Units + Zero Clearing

How to clear the logging memory using button combination.

Peak Button Usage

How to record readings when logging type is 'On Demand'.

Ultra Low Power (ULP) Mode

How to use ULP mode for extended logging periods.

Operating Behavior

Describes gauge behavior during data logging.

Reset or Battery Change Impact

How resets or battery changes affect logged data and clock.

Excel Templates

Excel Template Usage

How DataLoggerXP interfaces with Excel for reporting.

Excel Password Protection

How to password protect Excel workbooks.

Data Export to Excel

How data is copied to Excel and references are used.

Default Template File

How to select and set default Excel template files.

Enclosure

Information

Details on weight, housing, rating, and keypad material.

Dimensions and Details

Technical drawings and dimensions of the gauge enclosure.

Additional Sensor Lengths

Information on optional fitting adapters for sensors.

Serial Numbers

Serial Number Location

Where to find the serial number on the XP2i gauge.

Serial Numbering System

Explanation of the 6-digit serial number format.

Specifications

Accuracy

Details on linearity, hysteresis, repeatability, temp, and stability.

Vacuum to Full Scale

Specific accuracy figures for vacuum to full scale ranges.

Temperature Specifications

Operating and storage temperature ranges.

Media Compatibility

Lists compatible liquids and gases.

Pressure Conversions

Conversion factors for various pressure units.

Connections

Details on communication and pressure connection types.

Display Specifications

Information on screen size, digits, and readability.

Sensor Specifications

Details on wetted materials and diaphragm seal fluid.

Power

Information on battery type, life, and indicator.

Pressure Ranges, Display Scales, & Resolution

Table detailing pressure ranges, overpressure limits, and resolution.

Part Numbering System

Explains how XP2i part numbers are structured.

Safety & Certifications

Hazardous Locations Approvals

Details intrinsic safety approvals for hazardous environments.

General Safety Warnings

Provides crucial warnings for using the XP2i in hazardous areas.

Certifications and Standards

Lists international standards and directives the XP2i complies with.

Multilingual Safety Instructions

Safety and battery instructions in Czech, German, English, Spanish, French, Italian, Dutch, Polish, Finnish.

CSA Specific Certifications

Details battery approval requirements for CSA certification.

Support

Troubleshooting Guide

Addresses common issues, unstable readings, non-repeatability, and error displays.

Calibration Procedures

Covers factory adjustment, frequency, and span factor calibration.

Software, Parts & Accessories

Details ConfigXP software, replacement parts, and available accessories.

Contact Us

Factory Service

Procedure for obtaining factory service and return authorization.

Trademarks

Lists third-party trademarks mentioned in the manual.

Warranty

Details the warranty terms and conditions for the XP2i.