 EN • 11
EN
LEAD-ACID
ERROR LAMP
If the error lamp is lit, check the following:
TIME TO GO
AGM RECONDNORMAL
MODE
CAREGOTRY
HOURS124>8
1. Polarity error: Is the charger’s posi-
tive lead connected to the positive
charging point? Is the charger’s
negative lead connected to the
negative charging point?
2. Is the charger connected to a 12V
battery?
3. Has charging been interrupted in
CHECK or CARE?
Restart the charger by pressing the MODE-
button. If charging is still being interrupted, the
battery...
CHECK: ...is seriously sulphated and can not
accept charge. The battery may need to be
replaced.
CARE: ...can not keep charge. The battery may
need to be replaced.
POWER LAMP
If the power lamp is lit with a:
TIME TO GO
AGM RECONDNORMAL
MODE
CAREGOTRY
HOURS124>8
1. STEADY LIGHT
The mains cable is connected to the wall socket.
2. FLASHING LIGHT
The charger has entered the energy save mode.
This happens if the charger can’t detect a battery
in 2 minutes.