Read warning notices for safety in installation, use, and maintenance.
Guidelines for moving the pump vertically and handling claims upon delivery.
Use the pump only for its intended purpose of dosing liquid additives.
Check pump integrity, keep packing away from children, verify power supply.
Follow instructions for hazardous liquids and use correct materials for tubing and valves.
Consult exploded views for assembly; follow specific steps for dismantling the pump.
Explains peristalsis via rollers compressing a tube to move fluid.
Manufactured according to regulations, PP housing, level control, standard power supply.
Details flow rate, pressure, weight, dimensions, power, rotation speed, and tube size.
Lists materials for hoses (Santoprene, Polypropylene, PVC Cristal, Polyethylene).
Observe local regulations, use circuit breakers, ensure circuits are open before access.
Install in a dry place, away from heat, consider liquid level and vapors.
Measures and settles pH and ORP values, operates in proportional mode.
Identifies buttons on the control panel (Increase, Decrease, Menu/ESC, CAL/OK, Set, Display).
Alerts for pH below 5 or above 9, or low mV for oxidant dosing.
How to put the pump into stand-by mode using button combinations.
Procedure to prime the pump while it is in stand-by mode.
Press MENU for 5 seconds to access operating parameters setup.
Navigate and select the desired language using specific buttons.
Choose between pH or other measurement types using navigation buttons.
Select the dosing mode, such as ACID (pH-) or other options.
Configure the auxiliary input, for example, to activate or deactivate the recirculation pump.
Set the desired pH or ORP value by increasing or decreasing it.
Press CAL/OK for 5 seconds to enter the calibration menu.
Step-by-step guide for calibrating the pH probe using buffer solutions.
Information on single-point calibration for redox measurement using a buffer solution.
Identifies calibration errors and indicates potential probe replacement.
The pump stops and displays "TANK LEVEL LOW" if the chemical is finished.
Diagram showing the service connector and the function of each pin.
Details the purpose of connectors 1-2 (Recirculation pump), 4-5 (Output relay), 7-8 (Alarm relay), 10-11 (Level probe).
Check chemical levels, inspect hose for tears, clean foot filter and injection valve.
Steps for cleaning the pump with water and hydrochloric acid.
Addresses issues like loose nuts, broken tubes, or additive residue.
Troubleshoots issues like tube integrity, filter clogging, or injection valve clogging.
Checks controller calibration and electrode efficacy.
Ensures correct setpoint and jumper position for dosing.
Checks level switch connection and short circuit poles; contact support if needed.
Identifies main pump components with position numbers and part codes.
Lists spare parts like motors, rotors, electronic boards, tubes, and calibration solutions.
Visual guide for navigating the setting menu to select language, measurement type, dosing mode, and auxiliary input.