Conditions for Use
03
CAUTION
DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN
QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM
THIS DRINKING WATER SYSTEM IS FOR USE ON POTABLE COLD WATER SUPPLIES ONLY
Source Water Supply
Municipal/Private: Potable Water Supply
System Pressure: 25~80 PSI (1.7-6.9 bar) (for RO to work properly, water pressure
should be between 60-70 PSI)
Temperature: 40°~100°F (4°~38°C)
Warning
A pressure regulator must be installed before the system water inlet if the water pressure
or any possible pressure spikes could exceed 80 PSI (5.5 bar) Failure to comply will void
all warranties. The manufacturer accepts no liability for any damage caused by exces-
sive water pressure.
Environmental Conditions
System should be installed in areas that are protected from severe environmental condi-
tions. System is not manufactured or approved for installation in areas that are
exposed to direct sunlight, rain/snow and/or extreme temperature variation.
Compliance
Installation and service must be performed by qualified personnel to ensure compliance
with all applicable local, state, federal and international codes.
Note:
Always check applicable plumbing codes before tapping into a water or drain line.