15
PRO-VISION rev.04
PRO-VISION
Temp.
Sensors
Heater
Unused FansUnused Fans
Unused Fans
Unused Fans
Clean Mode
Heaters
Heater
Heaters
Temp.
Sensors
Temp.
Sensor
Select:1.
Main menu
* Start Flock
* A password may be required to access this menu
(see section 4.2.1).
Start flock
To modify use
-
Mortality
Loss (%)
Stat Flock
Age
Clean Mode
Remaining
Birds placed
Age
Program
New Mortality
Alarm low T°?
0
0.00
No
1
On
10000
10000
Program 1
0
No
Set the following parameters:2.
Clean M o d e Select On” to enable the clean
mode or select “Off to disable it.
Al a r m l ow T° Select Yes” for the controller
to s e t of f an alarm when the average te mpera -
ture gets lower than the Non Brood Set Point
while the controller is in clean mode. *This
parameter is accessible if the clean mode is enabled
above or if an empty zone is used.
Figure: Heaters in Clean Mode
4.9. Test Mode
The test mode is used to simulate changes in
th e ambient temperatu re and ve rif y the control -
lers performa nce. Whe n the test is e nab le d, all
outputs of the controller operate according to
the simulated temperature. The test automati-
cally ends after 15 minutes of inactivity or if
the user deactivates it manually.
Select:1.
Main menu
* Set-up
Test Mode
* A complete-access password may be required to
access this menu (see sec. 4.2.1).
Test Mode
Program
Temperature
Status
Stat.Pressure
Program 1
0.0
Off
0.00
Set the following parameters:2.
Program # This is the program that is cur-
rently used by the controller. It is displayed for
information only. *Refer to section 4.3 to change
the program in use.
Status Select On” to enable the test mode
or select “Off to disable it.
Temperature Set the simulated room tem-
perature to the desired value. * This parameter
is accessible if the test mode is enabled above.
Stat. Pressure This is the current level of
static pressure. It is displayed for information
on ly and cannot b e modifi e d ma nually. * This
parameter is accessible if the test mode is enabled
above and if a static pressure sensor is enabled in
the Set-up menu (see section 4.4).
4.10. Version
The version menu gives the version number
of the program used by the controller. This
piece of information is useful to get techni-
cal support.
Select:1.
Main menu
* Set-up
Version
* A complete-access password may be required to
access this menu (see sec. 4.2.1).
Pro-vision
V X.X
Build no. XXXX
Released: Jan 1 200X