EasyManua.ls Logo

Cumberland PRO-VISION - 17. TECHNICAL SPECIFICATIONS

Cumberland PRO-VISION
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
43
PRO-VISION rev.04
PRO-VISION
17. TECHNICAL SPECIFICATIONS
Type .....................................................................PRO-VISION
Main supply fuse F1 ............................................... 1A, fast-blow
Main supply/frequency ...........................................115/230 VAC, 50/60Hz, 1 phase, 30W max.
Enclosure ..............................................................ABS, moisture and dust-tight
Operating temperature ...........................................32 to 104°F (0 to 40°C)
Storage temperature ..............................................5 to 122°F (-15 to 50°C)
Ambient relative humidity.......................................Max. 95%
Pollution degree.....................................................2
Altitude ................................................................Up to 2000m
Outputs:
14Vdc outputs ......................................................14 Vdc±10%, regulated, 350 mA max
0-10V outputs #1-2 ...............................................0-10Vdc, 30mA source max
Precision on 0-10V outputs ....................................±1 %
Alarm contact .......................................................24 Vac or dc max, 0.15 A
Inputs:
Relative humidity input ..........................................4-20mA
Static pressure input ..............................................4-20mA
Temperature inputs ................................................1K @ 77°F (25°C), NTC
Ammonia sensor ....................................................4-20mA
Wind speed sensor ................................................Pulse 2.5mph/Hz
Feeders 1-4 ..........................................................Dry contact
Water meters 1-2 ...................................................Input pulse width > 12ms, 60Hz max