11
Gas Connection
Installation Relevant to Natural Gas
Installation to Natural Gas must conform to the Industry Standards, etc. The supply pressure for Natural Gas is 20 mbar.
Installation Relevant to Liquid Petroleum Gas (LPG)
This appliance must only be connected to LPG after an LPG
conversion kit has been tted. The installation must conform
to the relevant British Standards.
• The installation of the cooker to Natural Gas or LP Gas must be carried out by a Gas Safe registered
engineer. Installers must take account of the provisions of the relevant British Standards Code of
Practice, the Gas Safety Regulations and the Building Regulations.
• The gas connection to the cooker must be installed with a exible connecting tube made to BS669.
• Only a suitably qualied and Gas Safe Registered Engineer may
convert the appliance to a dierent gas type.
• When using Butane gas a supply pressure of 28 -30 mbar is required.
• When using Propane gas a supply pressure of 37 mbar is required.
• Flexible hoses can be used where the sited ambient temperature of
the hose does not exceed 70°C. These hoses must be manufactured
in accordance with BS669 part 1 or BS EN 14800 and be of the correct
construction for the type of gas being used.
• Gas hoses designed for natural gas MUST NOT be used for supplying
LPG gas (LPG gas hoses can be identied by a either a red band or
stripe on the rubber outer coating of the hose).
• The hose should not be crushed or trapped or be in contact with
sharp or abrasive edges. It should also not be subjected to corrosion
by acidic cleansing agents.
* All images are for indication only; please refer to your individual unit for actual item.
To Connect the Gas Supply:
1. Connect the gas supply to the right gas inlet at the rear of the cooker. The gas hose must hang in a “U” behind
the cooker and not drag on the oor.
2. Undertake a full gas tightness test.
3. To avoid damage to the appliance gas rail inlet pipe tighten the ttings using two suitable spanners.
4. Using a suitable leak detection uid solution check each gas connection one at a time by brushing the
solution over the connection. The presence of bubbles will indicate a leak. If there is a leak, tighten the tting
and then recheck for leaks.
Do not use a naked ame to test for leaks.
Currys Essentials Freestanding Gas Cooker CFSGSV18 Manual.indd 11Currys Essentials Freestanding Gas Cooker CFSGSV18 Manual.indd 11 14/01/2021 16:4314/01/2021 16:43