Curtis 1356/1356P CAN Expansion Module Manual, Rev. A
43
ANALOG INPUT PROGRAM MENU *
ALLOWABLE
PARAMETER RANGE DESCRIPTION
Input Type 0, 1 Selects the analog type:
0 = Voltage type input.
1 = Resistive type input.
High Threshold 0.0 15.0 V Sets the threshold the analog input must go above
to set the virtual digital input High.
Low Threshold
0.0 15.0 V Sets the threshold the analog input must go below
to set the virtual digital input Low.
Filter Gain
1–16384 Setstheamountoflteringontheinput.
Highergainsprovidefasterltering.Filteringaffects
the analog reading and the virtual digital input
responsiveness.
* This menu is repeated for Analog Inputs 1 5.
DIGITAL INPUT PROGRAM MENU
ALLOWABLE
PARAMETER RANGE DESCRIPTION
Input1 Debounce Time 8 1000 ms Sets the debounce time of Digital
Input 1 in 8ms steps.
Input2 Debounce Time
8 1000 ms Sets the debounce time of Digital
Input 2 in 8ms steps.
. . .
Input13 Debounce Time 8 1000 ms Sets the debounce time of Digital
Input 13 in 8ms steps.