44
Curtis 1356/1356P CAN Expansion Module Manual, Rev. A
ENCODER PROGRAM MENU
ALLOWABLE
PARAMETER RANGE DESCRIPTION
Encoder Type 0 –4 3 Selects the encoder type:
0 = Encoder disabled.
1 = Pulse count type.
2 = RPM type.
3 = Position type.
Must cycle KSI for new encoder type
to take effect.
Pulse Per Meter
0 65535 This parameter should be set according to the
pulses per revolution and displacement per
revolution of the encoder:
Pulse Per Meter =
pulses per revolution
displacement per revolution (unit m)
Pulse Per Revolution
0 65535 This parameter should be set according to the
encoderspecication.MustcycleKSIfornew
setting to take effect.
Swap Direction 0, 1 Sets the positive phase direction:
0 = Positive phase when phase A is
ahead of phase B
1 = Positive phase when phase B is
ahead of Phase A.
Must cycle KSI for new setting to take effect.
Reset
0 Sets the encoder counter to zero.
7 — PROGRAMMER: PROGRAM MENUS