EasyManua.ls Logo

CUTES CT-2000F Series - 11 Function Code Table

Default Icon
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C.TY TNHH TỰ ĐỘNG HÓA VIỆT TRUNG 02413.281.181-0989.984.666
Website:www.viet-trung.com.vn Đ/c:194-Nguyễn Trãi-Võ Cường-TP.Bắc Ninh
103
Function Code Table
11.
Function
Code
Table
Code
No.
Function Detail of Data Initial factory
setting
MODBUS
Address
Cd00 Set frequency 0.5-240Hz 10 128
Cd01 Frequency setting
procedure
Cd02 Select monitor
display data
0: Operation panel Cd00
1: External IN2 (0-10V)
2: External IN1 (4-20mA)
3: External IN2+IN3 (0-10V)
4: External IN2 (0-10V)hysteresis
5: External IN1 (4-20mA)hysteresis
6: External IN2+IN3 (0-10V)
hysteresis
7: Multi-steps control
0: Frequency (HZ)
1: Current (A)
2: Ultimate speed
3: DC Voltage(d)
4: Output AC Voltage(V)
5: External I/O status(E)
6: Temperature of PIM module(b)
7: operation frequency feedback
8: average speed of multi-step
function.
9: current step of multi-step function
10: current time of multi-step
function (min)
11: Yards counter
12: power factor
13: transient power (Kw)
14: KWh
15: MWh
5 129
0 130
Cd03 Torque mode 0: Without auto boost
1: 3Hz above with auto boost
2: 1.5Hz above with auto boost and
frequency compensation
3Hz above without frequency
c