Adjust and Function Specification
Item of display
changing
Parameter
selection
Parameter
modification
Press,key at display mode, select required item.
Press ,key to change value when screen
shows Cd- (General parameter input area) or
CE- (Failure display and engineering mode). Press and
hold ,key can progressively increase or
decrease value.
Press ,key at parameter input mode can change
parameter. Using with SET key to modify parameter.
Input a number Input a number
0
9
D. Function Code
§Cd00 Set frequency (settable range 0.5-240 HZ)
There are 5 methods to change set frequency. Items A~C are methods of panel key
operation, items D-E are methods of external terminal input.
A. At display function, press READ and setting (Cd01=0)
B. Use PROG key to input data (Cd01=0)
C. Use ▼、▲ key to input data (Cd01=0)
D. Use Multi-Step function to setting (Refer to function CE05 to CE55.)
E. Set external voltage
F. Set external current
Note:
1. Set value should be in accordance with V/F slope (Cd05) and upper limit
frequency (Cd17).
Set by function key
A. At display function, press READ and setting (Cd01=0)