105
Function Code Table
Code
No.
Function Detail of Data Initial factory
setting
MODBUS
Address
Cd05 V/F pattern 1-10 fixed Modes
11: Set by CD57, CD58
12: 1.5 power curve
13: 1.7 power curve
14: square curve
2 133
Cd06 Motor rated
current
25-100% 100 134
Cd07 Torque boost 0-15.0 (0-15.0%) 5 135
Cd08 1
st
acceleration
time
Cd09 1
st
deceleration
time
Cd10 2
nd
acceleration
time
Cd11 2
nd
deceleration
time
0.1-6000 (S/50HZ) 5 136
0.1-6000 (S/50HZ) 5 137
0.1-6000 (S/50HZ) 10 138
0.1-6000 (S/50HZ) 10 139
Cd12 No.2 frequency HZ 20 140
Cd13 No.3 frequency HZ 30 141
Cd14 No.4 frequency HZ 40 142
Cd15 Jogging frequency 0.5HZ-30HZ 5 143
Cd16 Start frequency 0.5HZ-60HZ 1 144
Cd17 Upper limit
frequency
Cd18 Lower limit
frequency
Cd19 Jogging
acceleration /
deceleration time
10-240HZ 60 145
0-100HZ 0 146
0.1-10 (S/50HZ) 1 147
Cd20 Jump frequency 1 HZ 0 148
Cd21 Jump frequency 2 HZ 0 149
Cd22 Jump frequency
width