Home Screen:
Default display which shows the baery voltage, if the solar panels are charging,
and if the load output is engaged.
From the home screen, short press “menu” to view the status of all parameters.
When you get to a seng you want to change, long press “menu” for 3 seconds to enter “edit mode”. Aer
the seng is adjusted, to save: short press “menu” or just wait for the screen to me out.
PV OFF:
The voltage at which solar charging will be disconnected. PV OFF should be the
maximum voltage you want your baery/baeries to be charged. (Typ.
Note: this MUST be modied for LiFePO4 baeries!! Refer to your baery speci-
caons!
LOAD ON (Voltage):
The voltage at which the load output will be engaged (if allowed by me seng).
LOAD OFF:
The voltage at which the load output will be disconnected. This is a protecve
seng to prevent the baery from overdischarging.
LOAD ON (Time):
The me at which the load output can be engaged. 24h means the load will al-
ways be on as long as the voltage doesn't drop below “LOAD OFF”. 1-15h means
the load output will be engaged for this many hours aer the charge controller no
longer detects the solar panel (sunset). 0h acvates the “dusk to dawn” seng;
load will be set to engage at dusk and disengage at dawn.
b1, b2, b3, b4 These are preset sengs and can be disregarded.
The other displays are status indicators/parameters.
SCREEN GUIDE:
Sengs that are adjusted will be automacally saved, even if power is removed.