CyberPower CP600LCD Replacement Guide

CyberPower CP600LCD
1 page
Page #1 background imageLoading...
Page #1 background image
+
-
-
+
-
+
-
+
1
32
MODEL: CP850AVRLCD, CP1000AVRLCD
1
2
3
1. Place the UPS on its top and remove the retaining screw (figure 1).
2. Slide the battery compartment cover completely off of the unit (figure 2).
3. Remove the battery from the compartment and disconnect the battery wires from the battery. Install the replacement
battery by connecting the red wire to the positive (+) terminal and the black wire to the negative (-) terminal of the
battery. (figure 3)
4. Slide the battery compartment cover over the battery and tighten the retaining screw.
5. Charge the unit for 4 – 8 hours to ensure the UPS performs expected runtimes.
1. Place the UPS on its side and locate the battery compartment cover on the bottom of the UPS. Remove the four (4)
retaining screws and pull the battery compartment cover off the UPS (figure 1 & 2).
2. Remove the battery from the compartment and disconnect the battery wires from the batteries. Install the
replacement batteries by connecting the red wire and black wire to the same color wires from the battery pack. Put
the battery pack into the compartment (figure 3).
3. Slide the battery compartment cover over the battery and tighten the retaining screw. Charge the unit for 4 – 8 hours
to ensure the UPS performs expected runtimes.
1. Carefully turn the UPS on its side. Remove the 6 retaining screws and the cover.
2. Disconnect the black and red cable from the battery set.
3. Remove the battery protection cover and take the battery pack out of the compartment.
4. Slide a new battery pack into the unit. Assemble the battery protection cover,cable, screws in the reverse order of
the previous steps. Recharge the unit for 4-8 hours to ensure the UPS performs expected runtime.
1. Carefully placed the UPS on its side. Remove the 2 retaining screws then push the battery cover backward and
remove the cover.
2. Disconnect the battery wires from the battery, and then remove the battery from the compartment.
REMINDER: For PP800/PP1100/PP1500T, 2 batteries are attached with one single plastic strip. You can pull the
plastic strip to pull out the battery.
3. Install the replacement battery by connecting the red wire to the positive (+) terminal of the battery and connecting
the black wire to the negative (-) terminal of the battery.
4. Slide the battery back into the compartment. Carefully turn the UPS upside down to help the batteries slide all the
way into the compartment. Replace the cover and the retaining screws. Recharge the unit for 4 – 8 hours to ensure
the UPS performs expected runtime.
1. Place the UPS on its side to locate and remove the front panel retaining screws from the bottom of the UPS.
2. Slide the cover (front panel) towards the bottom of the UPS.
3. Remove it from the unit.
4. Disconnect the cable located at the top of the cover.
5. Disconnect the battery wires from the batteries.
6. Remove the batteries from the compartment.
7. Install the replacement batteries by connecting the red and black wires to the same color wires from the battery
pack. Put the battery pack back into the compartment.
8. Replace the battery compartment cover and tighten the retaining screw. Charge the unit for 4-8 hours to ensure the
UPS performs expected runtimes.
Intelligent LCD Series
1
2
3
6
4
5
AVR Series
1
3 4
2
Professional Tower Series
MODEL: PP800SW
MODEL: PP1500SWT4, PP2200SW
1 2
4
3
K09-0000065-00
BATTERY REPLACEMENT
K09-0000065-00
BATTERY REPLACEMENT
MODEL: CP600LCD, CP825LCD, CP800AVR, CP685AVR-G, CP825AVR-G, CP685AVRLCD-G,
CP825AVRLCD-G
MODEL: CP900AVR, CP1200AVR, CP1500AVRT, CP1285AVRLCD, CP1350AVRLCD,
CP1500AVRLCD

Other manuals for CyberPower CP600LCD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CyberPower CP600LCD and is the answer not in the manual?

CyberPower CP600LCD Specifications

General IconGeneral
Output power340 W
UPS topologyStandby (Offline)
Input frequency60 Hz
Maximum current- A
Audible alarm(s)Yes
Surge energy rating1030 J
Output power capacity0.6 kVA
Weight (imperial)14 lbs
Dimensions (WxDxH)279.4 x 165.1 x 89 mm
Operating temperature (T-T)32 - 95 °F
Dimensions (W x D x H) (imperial)11 x 3.5 x 6.5 \
Battery recharge time8 h
Typical backup time at full load2 min
Typical backup time at half load9 min
Modem (RJ-11) ports1
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Operating relative humidity (H-H)0 - 95 %
CertificationUL1778, cUL 107.1, FCC DOC Class B
Weight and Dimensions IconWeight and Dimensions
Weight6350 g

Related product manuals