5
Command Name Description Description of parameter
SOURCE N SOURCE SELECTION N=0/Optical, 1/RCA IN or
?
VOL N
OUTPUT VOLUME
SETTING
N=-40~10dB (0) or
?
MUTE N
OUTPUT VOLUME
MUTE CONTROL
N=0(Unmute), 1(Mute) or
?
MONO N
SET MOMO OR
STEREO MODE
N=0(Stereo), 1(Mono) or
?
NAME N1 N2 SET INPUT NAME
N1=0(Optical), 1(RCA)
N2=Up to 24 Characters or
?
IPCONFIG
SHOW IP
CONFIGURATION
STATUS
None
SIPADDR N
SET ETHERNET IP
ADDRESS
N=X.X.X.X
X=0~255 (192.168.1.50)
SNETMASK N
SET ETHERNET
NETMASK
N=X.X.X.X
X=0~255 (255.255.255.0)
SGATEWAY N
SET ETHERNET
GATEWAY
N=X.X.X.X
X=0~255 (192.168.5.254)
RSTIP
IP CONFIGURATION
RESET TO <DHCP>
None (Statics)
VER
SHOW UNIT
FIRMWARE VERSION
None
REBOOT SYSTEM REBOOT None
FADEFAULT FACTORY RESET None
ETH_FADEFAULT
ETHERNET
PARAMETER SET
FACTORY DEFAULT
None
?
SHOW COMMAND
LIST
None
HELP
SHOW COMMAND
LIST
None
Note: All the RS-232 command will be not executed unless followed
with a carriage return. All commands are case-sensitive