Questions and Answers

  • B
    Brian LewisAug 2, 2025
    Why does my DAB GENIX VT motor work continuously?
    • S
      Susan KellerAug 2, 2025
      If your DAB Water Pump motor runs continuously or starts at regular intervals, it could be due to several reasons. First, check for water leaking from inlet into the tank or water leaking back into the tank from the discharge pipe. You may need to check for leaking appliances or check the non-return flap. Another possible cause is a defective pressure switch, which would require replacing the pressure switch unit. Finally, excess foam could be the problem; in this case, check the air vent, ensure the basin is connected to the top connection, or provide an air vent.
  • D
    Debra WilliamsAug 6, 2025
    Why is my DAB GENIX VT Water Pump making a rattling noise?
    • D
      dixondeanAug 6, 2025
      If you hear a rattling noise from the DAB Water Pump lifting station, but water is still being evacuated, it is likely due to a foreign body hitting the impeller or grinder. To resolve this, remove the foreign body.
  • C
    Cynthia MurphyAug 10, 2025
    What to do if DAB GENIX VT motor does not start?
    • T
      Terry KellyAug 10, 2025
      If your DAB Water Pump motor doesn't start and makes no noise when the water level is reached, several issues could be the cause. First, check for a supply failure and reestablish the power supply. Second, inspect the protection fuses and replace any blown fuses. If the new fuse burns out, the cable or motor may be faulty and require replacement. A blocked impeller can also prevent the motor from starting; in this case, free the impeller and allow the motor to cool down until the thermal switch resets. Lastly, a blocked pressure switch pipe could be the issue; remove the pipe and clean it.
  • M
    Mrs. Jill SchroederAug 14, 2025
    What to do if DAB Water Pump runs but does not pump water?
    • R
      Rebecca MilesAug 14, 2025
      If the DAB Water Pump motor runs but does not evacuate water, there are a few potential causes. The pump or tank might be blocked, so remove any blockage. Alternatively, there could be an air lock in the pump or a blocked vent hole in the pump housing. Check the operation of the vent valve in the tank, ensure the carbon filter is not wet and verify that the vent hole in the pump housing is not blocked.
  • N
    newtonbrandiAug 19, 2025
    Why is my DAB Water Pump service station draining slowly?
    • W
      wendy99Sep 12, 2025
      If your DAB Water Pump service station drains slowly, it could be due to a few reasons. The discharge pipe might be too long or have too many bends; consider increasing the pipe size, reducing the number of bends, or using soft bends. Another cause could be a leaky pump housing, which would require replacing the pump housing. Lastly, the hydraulics or grinder could be blocked; check and clean them.
  • S
    stevenhoffmanAug 23, 2025
    How to fix a DAB Water Pump motor that hums but doesn't start?
    • A
      Amy GoodwinAug 23, 2025
      If your DAB Water Pump motor hums but does not operate, it could be due to a few reasons. The impeller might be stuck, so free the impeller and check that it can rotate freely. Another possibility is a defective motor or capacitor, which would require replacing the motor or capacitor. Lastly, the control board might be defective, requiring replacement.
  • C
    Christopher DelgadoAug 27, 2025
    How to eliminate odour from DAB GENIX VT tank?
    • J
      jim51Aug 27, 2025
      If you notice an odor coming from the DAB Water Pump tank, it is likely that the carbon filter is contaminated. Replace the carbon filter to resolve this issue.

Summary

Quick Guide GENIX VT

Control Panel Elements

Product Disposal (GB)

DAB GENIX VT Specifications

General IconGeneral
Maximum Head12 m
Maximum Flow Rate12 m3/h
Maximum System Pressure10 bar
ConnectionsDN 25, DN 32
Max Flow Rate12 m3/h
Max Head12 m
Max Pressure10 bar
Inlet/Outlet SizeDN 25, DN 32