Installation & Maintenance
Instructions
VA - VB
A - B
VD - VS

Questions and Answers

  • E
    ericgonzalezAug 9, 2025
    Why is my DAB VA 35/180 Water Pump so noisy?
    • S
      Sarah WarrenAug 9, 2025
      If your DAB Water Pump is noisy, there might be air trapped inside. Try bleeding the pump to remove any air. Also, check if the intake pressure is too low and increase it if necessary.
  • J
    Jason BarberAug 17, 2025
    How to reduce noise in my DAB Water Pump system?
    • K
      Kyle GarciaAug 17, 2025
      If your DAB Water Pump system is producing excessive noise, it could be due to a flow rate that is too high. Try selecting a lower speed. Another possible cause is air in the system, so try bleeding the system to remove any trapped air.
  • H
    Heather PruittAug 23, 2025
    How to troubleshoot a DAB VA 35/180 Water Pump that does not start?
    • Q
      qandradeAug 23, 2025
      If your DAB Water Pump doesn't start, begin by checking the electrical connections and fuses to ensure there's a supply voltage. Verify that the supply voltage matches the data on the pump's plate. For single-phase motors, a faulty capacitor could be the issue, so consider changing it. Lastly, the rotor might be blocked by deposits; select the maximum speed or manually free it with a screwdriver.
  • J
    Jordan MurilloSep 1, 2025
    What to do if my DAB VA 35/180 starts and then stops after a short time?
    • P
      Patty Roberts MDSep 1, 2025
      If your DAB Water Pump starts and then stops shortly after, it might be due to dirt or scale interfering with the rotor and stator lining, or between the impeller and pump body. Ensure the shaft turns freely and remove any dirt or scale.

Summary

Declaration of Conformity

General Warnings

Applications

Installation Instructions

Guidance on pump installation, including pipe placement and shaft orientation.

Electrical Connection

Starting Up

Maintenance

Troubleshooting

DAB VA 35/180 Specifications

General IconGeneral
Maximum operating pressure10 bar
Power supplyElectric
Motor protection classIP55
Insulation classF
ShaftStainless Steel
Max Flow Rate35 m³/h
Max Head180 m
Frequency50 Hz
TypeCentrifugal Pump
Pump bodyStainless steel
ImpellerStainless steel
PhaseSingle Phase
Outlet Diameter1 inch