PLANNING
GUIDE
www.Dacor.com Phone: (800) 793-0093
Specications subject to change without notice.
Install all appliances according to accompanying installation instructions.
5.10
Epicure
®
Ranges
ER36D, ER48D
GAS - ELECTRICAL ACCESS DIMENSIONS
Model A B C
D E*
ER36D
5 5/8”
(142.9 mm)
18 3/8”
(466.7 mm)
10 3/4”
(273.0 mm)
13 11/16”
(347.7 mm)
7/8”
(22.2 mm)
ER48D
3 13/16”
(96.8 mm)
18 11/16”
(474.7 mm)
9 3/8”
(238.1 mm)
13 3/4”
(349.3 mm)
1 1/8”
(28.6 mm)
* The diameter on models equipped for use in Canada is ¼” (6.4mm) larger than
those stated. Canadian units come from the factory pre-wired with an appliance
cord. When installing an appliance cord on models that are not pre-wired, the hole
size must be increased to 1 1/8” (1 3/8” for model ER48D) by removing the conduit
bracket inside the range electrical access box.
48” (1219 mm)
Front of open door
Front of handle
Front edge of bull nose
Front panel
Rear of front panel/oven door
30 3/4” (781 mm)
(483 mm)
(908 mm)
(940 mm)
(76 mm)
24” (610 mm)
(51 mm)
(387 mm)
(40 mm)
(229 mm)
(229 mm)
29 3/8” (746 mm)
28 1/4” (718 mm)
26 1/8” (664 mm)
**
**
**
** Optional
1 1/16” (27 mm) to cooking
surface (top of grates) from
top of trim
Finished side
panel
Width: ER36D - 35 7/8” (911 mm)
ER48D - 47 7/8” (1216 mm)
B
A
C
D
Gas regulator access,
cover removed
Range electrical access,
cover removed
E Electrical connection
hole in bottom
Inlet
Back of range
Product tolerances: +/- 1/16” (+/- 1.6 mm) unless otherwise stated
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type Manifold Pressure
Minimum Gas Supply
Pressure
Natural Gas 5” Water Column 6” Water Column
Propane (LP) 10” Water Column 11” Water Column
* Maximum gas supply pressure 1/2 p.s.i. for all models
WARNING
Observe all governing codes and ordinances during planning •
and installation. Contact your local building department for
further information.
This appliance must be installed in accordance with the •
accompanying installation instructions.
ELECTRIC CIRCUIT REQUIREMENTS
Range Model Circuit Required Total Connected Load
ER36D
240 Vac, 4-wire* 60 Hz, 30
Amp. (Min.) 40 Amp. (Recom-
mended)
6.5 kW (28 Amp.)
ER48D
240 Vac, 4-wire* 60 Hz, 50
Amp.
10.0 kW (42 Amp.)
* 4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground
Document # PG05 - 004 Revised 02/04/10 Page 1/2

Other manuals for Dacor Epicure ER36D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dacor Epicure ER36D and is the answer not in the manual?

Dacor Epicure ER36D Specifications

General IconGeneral
BrandDacor
ModelEpicure ER36D
CategoryRanges
LanguageEnglish

Related product manuals