WINTER OUTDOOR CONDITIONS
Indoor
Conditions
12°C D
11°C W
7°C D
6°C W
4°C D
3°C W
0°C D
-1°C W
-4°C D
-6°C W
-7°C D
-8°C W
Capacity kW 2.75 2.45 2.17 1.40 1.17
1.13
15°C
Input kW. 0.97 0.86 0.77 0.67 0.62
0.65
Capacity kW 2.60 2.33 2.10 1.33 1.23
1.09
18°C
Input kW. 0.99 0.86 0.78 0.71 0.68
0.68
Capacity kW 2.58
2.35
2.08 1.27 1.14 1.11
20°C
Input kW. 1.02
0.90
0.81 0.71 0.67 0.64
Capacity kW 2.40 2.29 1.99 1.07 1.15
1.07
22°C
Input kW. 0.94 0.89 0.81 0.70 0.68
0.63
5.3 DSB-G095L
SUMMER OUTDOOR TEMPERATURE DRY
Indoor
Conditions
25°C 30°C 35°C 40°C 45°C 50°C
Total capacity kW 2.44 2.32 2.16 1.98 1.82
1.70
Sensitive capacity kW 1.68 1.63 1.56 1.48 1.40
1.34
21°C D
15°C W
Input kW. 0.87 0.95 1.02 1.09 1.17
1.24
Total capacity kW 2.62 2.50 2.36 2.20 2.07
1.94
Sensitive capacity kW 1.78 1.73 1.67 1.61 1.56
1.54
24°C D
17°C W
Input kW. 0.87 0.95 1.03 1.11 1.20
1.28
Total capacity kW 2.80 2.75
2.60
2.40 2.18 1.99
Sensitive capacity kW 1.93 1.89
1.82
1.73 1.64 1.57
27°C D
19°C W
Input kW. 0.89 0.97
1.05
1.14 1.22 1.30
Total capacity kW 2.85 2.90 2.86 2.76 2.63
2.50
Sensitive capacity kW 1.83 1.85 1.84 1.81 1.78
1.79
32°C D
23°C W
Input kW. 0.88 0.98 1.07 1.17 1.27
1.37