EasyManua.ls Logo

Daewoo DWA-120C - User Manual

Daewoo DWA-120C
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
CONTENTS
1. Precaution
ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ
2
2. Specification
ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ
3
3. Wiring diagram
ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ
4
4. Structure and parts name
ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ
5
5. Function of main components
ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ
7
6. Trouble shooting guide
ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ
8
7. How to disassemble
ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ
10
8. Refrigerant cycle
ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ
11
9. Exploded diagram and parts list
ÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅÅ
12

Questions and Answers

  • M
    Michael HernandezAug 13, 2025
    Why is my Daewoo DWA-120C Air Conditioner running but not cooling properly?
    • M
      Michael DoughertyAug 13, 2025
      If your Daewoo Air Conditioner isn't cooling well even though both the fan and compressor are running, it could be due to a choked refrigerant system or compressor failure, requiring repair. Another possible cause is a refrigerant gas leak, in which case you should recharge the refrigerant gas.
  • J
    Jerome CarsonAug 17, 2025
    How to improve insufficient cooling in my Daewoo Air Conditioner?
    • J
      Jennifer LeeAug 17, 2025
      There are several reasons why your Daewoo Air Conditioner might not be cooling sufficiently: * The refrigerant system may be choked, requiring a check and repair. * The filter may need replacement. * There might be gas leakage in the heat exchanger of the condenser, which needs to be checked and repaired. * The refrigerant charge could be too high, needing repair and recharge. * The air filter may need cleaning. * The unit itself may need cleaning. * The unit may need shading from sunlight. * There might be an added heat source that needs removal.
  • R
    robertbrownAug 21, 2025
    What to do if fan motor and compressor do not run in Daewoo DWA-120C Air Conditioner?
    • J
      jessica52Aug 21, 2025
      If the fan motor and compressor of your Daewoo Air Conditioner aren't running, it could be due to a power failure. Consult your electric company. Alternatively, the circuit breaker might be tripped; in that case, try turning it on and off a few times. Finally, the power plug might not be making proper contact, so consider replacing it.
  • J
    jeffgonzalezAug 25, 2025
    What to do if Daewoo DWA-120C Air Conditioner has power but does not run?
    • K
      Kimberly PerkinsAug 26, 2025
      If your Daewoo Air Conditioner is supplying power, but the equipment isn't running, it could be due to a disconnection. In this case, repair or replace the receptacle. It could also be a mechanical failure of the switch. Then replace the cord or lead wire.
  • R
    Riley WhiteAug 28, 2025
    What to do if Daewoo DWA-120C compressor does not run in cool position?
    • M
      Melissa CookAug 28, 2025
      If the switch is in the 'cool' position but the compressor of your Daewoo Air Conditioner isn't running, replace the compressor or connection wire. Try turning the knob for a cooler setting. Also, repair or replace the switch. As a last resort, replace the unit.
  • F
    fescobarSep 1, 2025
    How to fix vibration and noise in Daewoo Air Conditioner?
    • M
      Maurice EvansSep 1, 2025
      If your Daewoo Air Conditioner is vibrating and making noise, ensure the unit is installed correctly. Imperfect installation can cause this issue, so the unit should be installed perfectly. Check if the fan is hitting anything and remove any obstacles. Also, tighten any loose screws or bolts, including those causing electrical noise. If none of these steps work, consider exchanging the components.
  • L
    Lindsay StephensSep 5, 2025
    Why am I getting an electric shock from my Daewoo Air Conditioner?
    • A
      ajenningsSep 5, 2025
      If you experience an electric shock or current leakage from your Daewoo Air Conditioner, it's likely due to an insulation defect in the wiring or lead wire. Replacing the defective parts is the suggested solution. It could also be due to current leakage caused by dew or rust, or a general insulation defect, both requiring replacement of the defective parts.
  • A
    Alexander MaloneSep 8, 2025
    How to stop water leakage into room from Daewoo DWA-120C?
    • J
      James WalkerSep 9, 2025
      If water is leaking into the room from your Daewoo Air Conditioner, it's likely because the mounting chassis isn't properly slanted to the outside. To fix this, ensure the rear side of the unit is lower than the front.

Summary

Precautions

Specifications

Wiring Diagrams

Structure and Parts Identification

External Structure and Parts Name

Identifies external components of the air conditioner unit.

Internal Structure and Parts Name

Details the internal components and their layout within the unit.

Main Component Functions

Troubleshooting Guide

Disassembly Procedures

Refrigerant Cycle Diagram

Exploded Diagrams and Parts Lists

Exploded Diagram (DWA-120 CT;DWB-120 CT;DWA-100 CT)

Visual breakdown of components for specific air conditioner models.

Parts List (DWA-120 CT;DWB-120 CT;DWA-100 CT)

Detailed list of parts with part codes for specific air conditioner models.

Exploded Diagram (DWA-120 C;DWB-120 C;DWA-100 C;DWB-090 C)

Visual breakdown of components for alternative air conditioner models.

Parts List (DWA-120 C;DWB-120 C;DWA-100 C;DWB-090 C)

Detailed list of parts with part codes for alternative air conditioner models.

Daewoo DWA-120C Specifications

General IconGeneral
Cooling Capacity12000 BTU/h
Power Supply220-240V, 50Hz
TypeWindow Air Conditioner
RefrigerantR-22
Power Consumption (Cooling)1200W
Air Flow450 m³/h
Operating Temperature (Cooling)18°C to 43°C

Related product manuals