EasyManua.ls Logo

Daewoo DWC-ED1213 - 4. ERROR DISPLAY

Daewoo DWC-ED1213
65 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
4. ERROR DISPLAY
ERROR
SINGAL
ERROR CAUSE COUNTERPLAN
1
inlet valve broken Change the Inlet-Valve
IE
WATER
2
drain motor working during water supply Change the Drain Motor
INLET ERROR
3
pressure switch disorder Change the Sensor Pressure
4
PCB can not check water level Change the PCB
1
drain motor out of order Change the Drain Motor
OE
DRAIN
2
inlet valve working during drain Change the Inlet-Valve
ERROR
3
pressure switch disorder Change the Sensor Pressure
4
PCB can not check water level Change the PCB
UE UNBALANCE ERROR
1
laundry unbalance rearrange the laundry
1
door opened during processing Clode the Door
LE
DOOR
2
LOCK S/W broken Change the LOCK SW
OPEN ERROR
3
PCB can not check door lock Change the PCB
1
continuous water supply Change the Inlet-Valve
E2 Overflow
2
drain motor can not work Change the Drain Motor
3
pressure switch disorder Change the Sensor Pressure
E3
FAN MOTOR
1
fan motor cannot work Change the Fan-Motor
disorder
2
PCB cannot control fan motor
The contact of the Connector or Change the PCB
E9
SENSOR PRESSURE
1
abnormal water level Change the Sensor Pressure
ERROR
1
huge noise re-installation
E5
HIGH VOLTAGE
2
spining with jamming clothes between gasket rearrange the laundry
ERROR
3
PCB broken Change the PCB
1
huge noise re-installation
E6 EMG ERROR
2
spining with jamming clothes between gasket rearrange the laundry
3
motor broken Change the Motor
4
PCB broken Change the PCB
E7 Direction Error
1
move opposite direction
2
motor Hall IC broken check the connector and change
E8 motor disorder
1
connector problem The contact of the Connector
2
abnormal loading condition check the loading condition and change
H1
sensor temp.
1
sensor temp broken Change the Sensor Temp.
dry disorder
2
connector problem The contact of the Connector
H2
sensor temp.
1
sensor temp. of washing broken Change the Sensor Temp.
wash disorder
2
connector problem The contact of the Connector
H3
overheating
1
fan motor cannot move Change the Fan Motor
dry heater
2
sensor temp. of dry broken Change the Sensor Temp.
H4
overheating
1
heater working with no water supply check water level
wash heater
2
sensor temp. of wash broken Change the Sensor Temp.
H6 abnormal of washing heater
1
washing heater cannot work Change the Heater Wash
H7 abnormal of drying heater
1
dry heater cannot work Change the Heater Dry
H8
abnormal of sensor temp.
1
heater working with no water supply
check the water level and washing heater
of washing
PEF Pump Filter
1
The drain filter is clogged. Clean the drain filter