45
• Situation : PCB shows "H7".
cause)
Dry heater is cut-off.
Fuse temp. is cut-off.
repaire method) replace the Dry heater.
replace the Fuse temp.
checking point part name checking results repaire method
HEATER
SENSOR TEMP.
FUSE TEMP.
dry Heater is short or cut-off.
Thermistor is short or cut-off.
FUSE TEMPERATURE is cut-off.
replace the
dry Heater.
replace the
Thermistor.
replace the
FUSE
TEMPERATURE.
HEATER
THERMISTOR
FUSE TEMPERATURE