EasyManua.ls Logo

Daewoo DWC-UD121DC - 5. TEST MODE; 5-1. Testing Mode; 5-2. Continous testing mode

Daewoo DWC-UD121DC
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
5-1. Testing Mode
PCB and other electronic parts will be tested without water supply whether they are normal or not.
1) Process
press power button --> press "SPIN" button 3 times with pressing "WASH" button --> 'L d' will be shown on LED -->
Whenever pressing "TEMP" button 1 time, below process will be occurred.
MICOM Ver. --> L C (Lock Closed) --> run (count) ---> b1, b2, b3, b4, b5, b6, b7
-> F (Fan Motor) -> H (Hot V/V)
-> C (Cold V/V) -> P (prewashing V/V) -> d ( dry V/V) -> bb (bubble)
-> dr (drain motor) -> L O(Lock S/W Open)
2) More details
1 When turn on 'LOCK' signal, all process is conducting normaly.
2 When working starts, the PCB displays all the sensor conditions.
3 In this case, BLDC Motor is not tested. In order to test it, select spin or rinse.
5-2. Continous testing mode
1) Process
after pressing "WASH", "RINSE", "SPIN" button simultaniously, press "POWER" button.
ALL LED On --> SPIN button ---> ALL LED off
--> L C (Lock Close) ---> r (Motor right) --> L (Motor Left)
--> F ( Fan Motor) ---> H (Hot V/V) --> C (Cold V/V) --> b (Pre whsh V/V) --> d ( dry V/V)
--> bb (bubble) --> h1 (Wash heater)--> h2(Dry heater) --> dr (Drain motor On)
-->L O(Lock S/W Open)
2) More tails
1 LED test can be done with all LED On.
2 All sensor conditions will be shown on PCB during processing.
5. TEST MODE

Related product manuals