28
Pcb Control Functions
NO CONTROL FUNCTION CONTENTS
15 Time charts of low E) General mode of Low temp. (RT24ºC)
temperature
F) General MODE (RT25ºC): deleting low temp function
ON POINT
OFF POINT
6min
COMP OFF
R-S
Comp
R-S
Heater
COMP ONCOMP ON
OFF POINT
COMP OFF COMP ON COMP OFF
25min ON 6min 25min ON
ON POINT
OFF POINT
COMP OFF
R-S
Comp
R-S
Heater
COMP ONCOMP ON
OFF POINT
COMP OFF COMP ON COMP OFF