1. Freezer Compartment Control
1) Adjust by the pushing the FRZ.SET button.
2) Compressor & Freezer Fan controlled by each mode ON/OFF point.
3) Freezer Compartment ON/OFF Difference : 2C
- MEDIUM OFF point : -19C
- When Room Temperature (RT) is below 13C, Freezer sensor OFF point 2C up ( so, MEDIUM OFF : -17C )
4) Control Temperature Point in Each Mode
FUNCTIONS ( TEMPERATURE CONTROL )
Initially On 1st Press 2nd Press 3rd Press 4th Press 5th Press 6th Press
-16 - 17
6) SUPER FRZ. (QUICK) Mode
- In this mode, Compressor & Freezer Fan motor is on unconditionally for 150min. ( free of freezer sensor )
Freezer
Sensor
Freezer
Fan On/Off
SUPER FRZ. Start
( SUPER FRZ. MODE )
NORMAL MODE
Start
150MIN
Sensor On -14.8 -15.8 -16.8 -17.8 -11.8 -12.8 -13.8
Sensor Off -16.8 -17.8 -18.8 -19.8 -13.8 -14.8 -15.8
Sensor On -12.8 -13.8 -14.8 -15.8 -9.8 -10.8 -11.8
Sensor Off -14.8 -15.8 -16.8 -17.8 -11.8 -12.8 -13.8
Normal
RT <= 13C