5.8 - Impeller Cleaning
Impeller cleaning is important when storing pump for long periods of time. It is also
advisable as part of regular maintenance checks.
QUICK METHOD
1. Fill pump with fresh water through primer opening.
2. Start pump and allow it to run for up to 8 minutes or until water
evaporates upon contact with engine block.
3. Drain water through pump drain outlet.
4. Flush pump with clean water (puring it through primer opening).
5. Reinsert drain screw.
INTENSIVE CLEANING
1. Remove / unscrew all 6 pump casing bolts from the pump.
2. Carefully remove the outside casing, exposing the impeller.
3. Clean impeller using regular soap and water, if necessary use a light
scrubbing tool to remove debris.
4. Reinstall casing on trash pump and fasten all bolts.
16