CAUTION:
1.
High
voltage
is
present
at
the
high
voltage
terminal
of
the
high
voltage
transformer
during
any
cook
cycle.
2.
It
is
neither
necessary
nor
advisable
to
attempt
measurement
of
the
high
voltage.
3.
Before
touching
any
oven
components
or
wiring,
always
unplug
the
oven
from
its
power
source
and
discharge
the
capacitor
(see
page
20).
1.
High
voltage
transformer
(A)
Remove
connections
from
the
transformer
ter-
minals
and
check
continuity.
(B)
Normal
readings
should
be
as
follows:
Secondary
winding
.....
Approx.
940
+5%
Filament
winding.............
Approx.
00
Primary
winding
.............
Approx.
12
2.
High
voltage
capacitor
(A)
Check
continuity
of
capacitor
with
meter
on
the
highest
OHM
scale.
(B)
A
normal
capacitor
will
show
continuity
for
a
short
time,
and
then
indicate
9MQ
once
the
capacitor
is
charged.
(C)
A
shorted
capacitor
will
show
continuous
con-
tinuity.
(D)
An
open
capacitor
will
show
constant
9MOQ.
(E)
Resistance
between
each
terminal
and
chas-
sis
should
be
infinite.
3.
High
voltage
diode
(A)
Isolate
the
diode
from
the
circuit
by
disconnect-
'
ing
the
leads.
(B)
With
the
ohmmeter
set
on
the
highest
resis-
tance
scale,
measure
the
resistance
across
the
diode
terminals.
41
Reverse
the
meter
leads
and
again
observe
the
resistance
reading.
Meter
with
6V,
9V
or
higher
voltage
batteries
should
be
used
to
check
the
front-to-back
resistance
of
the
diode,
otherwise
an
infinite
resistance
may
be
read
in
both
direc-
tions.
A
normal
diodes
resistance
will
be
infinite
in
one
direction
and
several
hundred
KQ
in
the
other
direction.
4.
Magnetron
For
complete
magnetron
diagnosis,
refer
to
“Measurement
of
the
microwave
output
power”
(Page
14)
continuity
checks
can
only
indicate
and
open
filament
or
a
shorted
magnetron.
To
diagnose
for
an
open
filament
or
shorted
magnetron.
(A)
Isolate
magnetron
from
the
circuit
by
discon-
ecting
the
leads.
(B)
A
continuity
check
across
magnetron
filament
terminals
should
indicate
one
ohm
or
less.
(C)
Acontinuity
check
between
each
filament
ter-
minal
and
magnetron
case
should
read
open.