1.
CIRCUIT
CHECK
PROCEDURE
1)
Low
Voltage
Transformer
(DMR-101FS)
Check.
The
low
voltage
transformer
is
located
on
the
P.C.B.
Measuring
condition:
Input
voltage:
230V
Frequency:
50Hz
K
FUSE
L
M
2)
Voltage
Check
Key
check
point
(MICOM
PIN)
NO.[
CHECK
POINT
ees
|
PIN
21
or
30
—5VDC
|
PIN
16
24VDC
OV
----
PIN
35
|
| |
|
|
|
T=20.0ms
(50Hz)
SV
"eT
PIN
31
or
32
_|
DP2
PIN
1
&
16
CHECK
METHOD
MP
2.0VAC
(DISPLAY
FILAMENT
VOLTAGE)