2. FUNCTIONS
- Compressor
- F Fan
- Defrost Heater
A. Defrost Mode Operation conditon
(1) In case accumulated compressor run times: 6, 8, 10, 12 hours,
- when there occur any errors:
R1, D1, C1, RT, Door SW error etc. (Check "2-9. ERROR DISPLAY")
- or, running rate of COMP (per 2hrs of accumulated operation time) is more than 90%
- or, accumulated door open time is over 2 minutes
- or, ambient temperature (RT) is more than 38
(2) Even if the above condition is not satisfied,
defrost mode starts immediately when accumulated compressor run time is 14hrs.
B. Normal Defrost Mode
C. Forced Defrost Mode
- How to start:
(1) by press Door S/W for continuously and Control 'Dial Knob'(MIN -> MAX) 1 times.
(2) or, by press 'Test Key' 3 times on Main PCB
- If appliance has any error, Forces Defrost Mode don't start.
- Process: same as Normal Defrost Mode except 'PRE-COOL'
Heater is supposed to be on Initial 30sec. even though the temp. at “D SENSOR” is
over 13. (for TEST)
- How to confirm: If Force Defrost Mode start, you can buzzer sound
CONTROL OBJECT
INPUT
- Accumulated Compressor Run Time
- Running Time Ratio of Compressor
- Accumulated Door Open Time
- Ambient temperature (RT)
2-3. Defrost Mode
'PRE-COOL'
Comp ON, Fan On, Heater OFF
Comp runs for 25min. before defrost mode
Defrost
Heater on
Comp OFF, Fan OFF, Heater ON
Heater off when 'D-Sensor' is over 10.
Heater off after 60min. at normal control.
Heater off after 40min. in case D1 error.
Pause
Comp OFF, Fan OFF, Heater OFF
10minutes.
Normal
Operation
12