User’s Manual
182
5.11.1.1 Configuring SMD Settings
Set SMD parameters. When the Device detects information, the system activates alarms.
Select Main Menu > SMART DETECTION > Parameters > SMD.
SMD
Select the channel and enable.
Set parameters.
Table 5-44 SMD parameters
Parameter
Description
Channel In the
Channel
list, select a channel to set the motion detection.
Enable Enable or disable SMD function.
Sensitivity
Set sensitivity, including high, middle, and low. The higher the sensitivity
is, the bigger alarm probability will be, the bigger false alarm rate will be.
The system selects middle by default.
Effective Target Select alarm object, including person and vehicle.
Schedule Define a period during which the motion detection is active.
Anti-Dither
Configure the time period from end of event detection to the stop of
alarm.
Alarm-out Port
Click
Setting
to display setting interface.
General Alarm: Enable alarm activation through the alarm devices
connected to the selected output port.
External Alarm: Enable alarm activation through the connected alarm
box.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dahua Technology XVR Cooper Series and is the answer not in the manual?

Dahua Technology XVR Cooper Series Specifications

General IconGeneral
BrandDahua Technology
ModelXVR Cooper Series
CategoryDVR
LanguageEnglish

Related product manuals