EasyManua.ls Logo

Daikin 2MKS40DVMB - Page 19

Daikin 2MKS40DVMB
230 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cooling Only SiBE12-519
10 Specifications
50Hz 230V
Duct Connected Type
50Hz 230V
Note:
1. The operating sound is based on the rear side suction inlet and the external static pressure 40 Pa.
Operating sound for under side suction inlet:[operating sound for rear side suction inlet ]+5 dB.
However, when installation to which the external static pressure becomes low is carried out,
5 dB or more may go up.
Model FTKS35CVMB(9)(8)
Rated Capacity 3.5kW Class
Front Panel Color White
Air Flow Rates
m³/min
(cfm)
H 7.7 (272)
M 6.0 (212)
L 4.4 (155)
SL 3.8 (134)
Fan
Type Cross Flow Fan
Motor Output W 18
Speed Steps 5 Steps, Silent, Auto
Air Direction Control Right, Left, Horizontal, Downward
Air Filter Removable-Washable-Mildew Proof
Running Current (Rated) A 0.18
Power Consumption (Rated) W 40
Power Factor % 96.6
Temperature Control Microcomputer Control
Dimensions (H×W×D) mm 273×784×195
Packaged Dimensions (H×W×D) mm 258×834×325
Weight kg 7.5
Gross Weight kg 11
Operation
Sound
H/M/L/SL dBA 39/33/26/23
Sound Power H dBA 57
Heat Insulation Both Liquid and Gas Pipes
Piping Connection
Liquid mm
φ
6.4
Gas mm
φ
9.5
Drain mm
φ
18.0
Drawing No. 3D044244B
Model FDKS25CVMB FDKS35CVMB
Rated Capacity 2.5kW Class 3.5kW Class
Front Panel Color
——
Air Flow Rates
m³/min
(cfm)
H 9.5 (335) 10.0 (353)
M 8.8 (311) 9.3 (328)
L 8.0 (282) 8.5 (300)
SL 6.7 (237) 7.0 (247)
Fan
Type Sirocco Fan Sirocco Fan
Motor Output W 62 62
Speed Steps 5 Steps, Silent, Auto 5 Steps, Silent, Auto
Air Filter Removable-Washable-Mildew Proof Removable-Washable-Mildew Proof
Running Current (Rated) A 0.47 0.47
Power Consumption (Rated) W 100 100
Power Factor % 92.5 92.5
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H×W×D) mm 200×900×620 200×900×620
Packaged Dimensions (H×W×D) mm 266×1,106×751 266×1,106×751
Weight kg 25 25
Gross Weight kg 31 31
Operation
Sound
H/M/L/SL dBA 35/33/31/29 35/33/31/29
External Static Pressure Pa 40 40
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Piping Connection
Liquid mm
φ
6.4
φ
6.4
Gas mm
φ
9.5
φ
9.5
Drain mm VP20 (O.D.
φ
26 / I.D.
φ
20) VP20 (O.D.
φ
26 / I.D.
φ
20)
Drawing No. 3D048947B 3D048948B
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3

Table of Contents