EasyManua.ls Logo

Daikin 2MXM40A2V1B - Page 70

Daikin 2MXM40A2V1B
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17 | Technical data
Installer reference guide
70
2MXM40+50A
R32 Split series
4P600463-4E – 2021.12
Compressor: category II
Other components: refer to PED article 4, paragraph 3
7.9CuT
7.9CuT
M
4.8CuT
4.8CuT
9.5CuT
7.9CuT
9.5CuT
9.5CuT
9.5CuT
9.5CuT
9.5CuT
6.4CuT
6.4CuT
EV
A
EV
B
9.5CuT
6.4CuT
6.4CuT
6.4CuT
9.5CuT
9.5CuT
HPS1
9.5CuT
(9.5CuT)
(12.7CuT)
(6.4CuT)
(6.4CuT)
a
b
c
d
e
f
g
g
h
i
j
A
B
A
B
k
l
l
m
n
o
o
p
q
r
s
t
n
m
i
h
g
c
c
2MXM50
A Room A k Field piping (liquid)
B Room B l Liquid stop valve
a 4-way valve ON: heating m Thermistor (liquid)
b High pressure switch with automatic reset n Filter
c Muffler o Motor-operated valve
d Discharge pipe thermistor p Muffler
e Compressor q Outdoor air temperature thermistor
f Accumulator r Heat exchanger
g Branch pipe M Fan motor
h Thermistor (gas) Refrigerant flow: cooling
i Gas stop valve Refrigerant flow: heating
j Field piping (gas)

Table of Contents

Other manuals for Daikin 2MXM40A2V1B

Related product manuals