Service
Manual
2MXS-N, 3/4MXS-R Series
SiUS121736EA
[Applied Models]
z Inverter Multi : Heat Pump
Multi-Split Type Air Conditioners

Table of Contents

Other manuals for Daikin 2MXS18NMVJUA

Questions and Answers:

Daikin 2MXS18NMVJUA Specifications

General IconGeneral
RefrigerantR-410A
Cooling Capacity18000 BTU
Power Supply208/230V, 60Hz
Indoor Unit Dimensions (W x H x D)Varies by indoor unit model
Indoor Unit WeightVaries by indoor unit model
Operating Temperature (Cooling)14°F to 115°F

Summary

Safety Cautions and Icons

Warnings and Cautions Regarding Safety of Workers

Safety warnings for personnel involved in maintenance and inspection of the equipment.

Warnings and Cautions Regarding Safety of Users

Safety warnings for users of the air conditioning equipment.

Printed Circuit Board Connector Wiring Diagrams

Functions and Control

Service Diagnosis and Troubleshooting

General Problem Symptoms and Check Items

Lists common problems and initial troubleshooting checks.

Troubleshooting with LED Indicators

Troubleshooting guide based on LED indicators on indoor and outdoor units.

Service Diagnosis Procedures

Diagnosis procedures for RA, SA indoor units, and outdoor units.

Troubleshooting RA Indoor Unit Errors

Specific troubleshooting steps for RA Indoor Unit errors.

Troubleshooting SA Indoor Unit Errors

Specific troubleshooting steps for SA Indoor Unit errors.

Troubleshooting Outdoor Unit Errors

Steps to diagnose and resolve issues with the outdoor unit.

Component Checks and Maintenance

Thermistor Resistance Check

Procedure to measure thermistor resistance using a multimeter.

Indoor Fan Motor Connector Check

Checks for proper connection and voltage of indoor fan motor connectors.

Hall IC Check

Procedure to check the Hall IC connection and output.

Power Supply Waveform Check

Measures and checks power supply waveform for disturbances.

Electronic Expansion Valve Check

Procedure to check the electronic expansion valve's latching sound and continuity.

Four Way Valve Performance Check

Checks the performance of the four way valve.

Inverter Unit Refrigerant System Check

Checks the refrigerant system of the inverter unit.

Inverter Analyzer Check

Procedure for checking inverter output using an inverter analyzer.

Main Circuit Short Check

Checks the main circuit for short circuits.