Instruction Si12-411A
138 System Configuration
2.8 OUTDOOR UNIT SILENT Operation
OUTDOOR UNIT SILENT Operation
OUTDOOR UNIT SILENT operation lowers the noise
level of the outdoor unit by changing the frequency and
fan speed on the outdoor unit. This function is conve-
nient during night.
To start OUTDOOR UNIT
SILENT operation
1. Press “SILENT button”.
To cancel OUTDOOR UNIT
SILENT operation
2. Press “SILENT button” again.
NOTE
Note on OUTDOOR UNIT SILENT operation
If using a multi system, this function will work only when the OUTDOOR UNIT SILENT
operation is set on all operated indoor units.
However, if using priority-room setting, see “Note for multi system”.
This function is available in COOL, HEAT, and AUTO modes.
(This is not available in FAN and DRY mode.)
POWERFUL operation and OUTDOOR UNIT SILENT operation cannot be used at the
same time.
Priority is given to POWERFUL operation.
If operation is stopped using the remote controller or the main unit ON/OFF switch when
using OUTDOOR UNIT SILENT operation, “ ”will remain on the remote controller
display.
C
TEMP
ON/OFF
POWERFUL
HOME LEAVE
MODE
TIMER
FAN
SWING
SILENT
SENSOR
ON
CANCEL
OFF
1, 2

Table of Contents

Other manuals for Daikin 3MXD68BVMA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin 3MXD68BVMA and is the answer not in the manual?

Daikin 3MXD68BVMA Specifications

General IconGeneral
CategoryAir conditioning
Cooling Capacity6.8 kW
Heating Capacity8.6 kW
Energy Efficiency RatingA++
RefrigerantR32
Power SourceElectric
Outdoor Unit Noise Level48 dB(A)
Power Supply220-240V, 50Hz