3 | Components
Service manual
95
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
b
e
c
d
a Domestic hot water exit
b Space heating exit
c Notch
d 3‑way valve body axle
e 3‑way valve knob
2 If needed, manually adjust the position of the 3‑way valve axle to align the
notch with the 3‑way valve motor.
3 Install the 3‑way valve motor on the 3‑way valve body.
4 Tighten the screw to fix the 3‑way valve motor to the 3‑way valve body.
a
a Screw
5 Install the 3‑way valve knob on the 3‑way valve motor.