EasyManua.ls Logo

Daikin Altherma 3 R F - Menu Structure: Overview User Settings

Daikin Altherma 3 R F
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 Electrical installation
Installation manual
18
EHVH04+08SU18+23EA
Daikin Altherma 3 R F
4P629088-1C – 2021.11
Item Description
WLAN module See:
Installation manual of the WLAN
module
Addendum book for optional
equipment
Installer reference guide
Use the cable delivered with the
WLAN module.
[D] Wireless gateway
Bizone kit See:
Installation manual of the bizone kit
Addendum book for optional
equipment
Use the cable delivered with the
bizone kit.
[9.P] Bizone kit
for room thermostat (wired or wireless):
In case of… See…
Wireless room thermostat Installation manual of the wireless
room thermostat
Addendum book for optional
equipment
Wired room thermostat
without multi-zoning base
unit
Installation manual of the wired room
thermostat
Addendum book for optional
equipment
Wired room thermostat
with multi-zoning base unit
Installation manual of the wired room
thermostat (digital or analogue) +
multi-zoning base unit
Addendum book for optional
equipment
In this case:
You need to connect the wired
room thermostat (digital or
analogue) to the multi-zoning base
unit
You need to connect the multi-
zoning base unit to the outdoor unit
For cooling/heating operation, you
also need to implement a relay
(field supply, see addendum book
for optional equipment)
6.3.1 To connect the main power supply
1 Open the following (see "4.2.1To open the indoor unit"[410]):
1 Top panel
1
2
3
2 User interface panel
3 Upper switch box cover
2 Connect the main power supply.
In case of normal kWh rate power supply
Interconnection
cable (=main
power supply)
Wires: (3+GND)×1.5mm²
A
1 2 3
a
B
A
B
1 2 3
X2M
X1A
X11YA
X11YB
X11Y
X1M
a
a Interconnection cable (=main power supply)
In case of preferential kWh rate power supply
Interconnection
cable (=main
power supply)
Wires: (3+GND)×1.5mm²
Normal kWh rate
power supply
Wires: 1N
Maximum running current: 6.3A
Preferential kWh
rate power supply
contact
Wires: 2×(0.75~1.25mm²)
Maximum length: 50m.
Preferential kWh rate power supply
contact: 16VDC detection (voltage
supplied by PCB). The voltage-free
contact shall ensure the minimum
applicable load of 15VDC, 10mA.
[9.8] Benefit kWh power supply
Connect X11Y to X11YB.

Table of Contents

Other manuals for Daikin Altherma 3 R F

Related product manuals