6 Electrical installation
Installation manual
19
EBBH/X11+16DF
Daikin Altherma 3 R W
4P643600-1B 2021.10
Item Description
LAN adapter See:
Installation manual of the LAN
adapter
Addendum book for optional
equipment
Wires: 2×(0.75~1.25mm²). Must be
sheathed.
Maximum length: 200m
See installation manual of the LAN
adapter
WLAN cartridge See:
Installation manual of the WLAN
cartridge
Installer reference guide
[D] Wireless gateway
WLAN module See:
Installation manual of the WLAN
module
Addendum book for optional
equipment
Installer reference guide
Use the cable delivered with the
WLAN module.
[D] Wireless gateway
Bizone kit See:
Installation manual of the bizone kit
Addendum book for optional
equipment
Use the cable delivered with the
bizone kit.
[9.P] Bizone kit
for room thermostat (wired or wireless):
In case of… See…
Wireless room thermostat Installation manual of the wireless
room thermostat
Addendum book for optional
equipment
Wired room thermostat
without multi-zoning base
unit
Installation manual of the wired room
thermostat
Addendum book for optional
equipment
In case of… See…
Wired room thermostat
with multi-zoning base unit
Installation manual of the wired room
thermostat (digital or analogue) +
multi-zoning base unit
Addendum book for optional
equipment
In this case:
You need to connect the wired
room thermostat (digital or
analogue) to the multi-zoning base
unit
You need to connect the multi-
zoning base unit to the outdoor unit
For cooling/heating operation, you
also need to implement a relay
(field supply, see addendum book
for optional equipment)
6.3.1 To connect the main power supply
1 Open the following (see "4.2.1To open the indoor unit"[413]):
1 Front panel
1
2
3
2 Switch box cover
3 Switch box
2 Connect the main power supply.
In case of normal kWh rate power supply
Interconnection
cable (=main
power supply)
Wires: (3+GND)×1.5mm²
B
C
A
A
a
1 2 3