14 Technical data
Installation and operation manual
40
EHYKOMB33A
Daikin Altherma hybrid heat pump – gas boiler module
4P353067-1H – 2018.10
EHYKOMB33AA*
Material Pre-coated sheet metal
Dimensions
Packing (H×W×D) 820×490×270mm
Unit (H×W×D) 710×450×240mm
Machine net weight 36kg
Packed machine weight 37kg
Packing material Carton/PP (straps)
Packing material (weight) 1kg
Main components
Water side heat exchanger Aluminium
Space heating water circuit
Space heating piping connections Ø22mm
Piping material Cu
Safety valve See indoor unit manual
Manometer Yes
Drain/fill valve No
EHYKOMB33AA*
Shut‑off valves No
Air purge valve Yes
Maximum pressure space heating
circuit
3bar
Domestic hot water circuit (not applicable for Switzerland)
Domestic hot water piping connections Ø15mm
Piping material Cu
Gas connection Ø15mm
Flue gas/combustion air connection Concentric connection
Ø60/100mm
Electrical
Power supply voltage 230V
Power supply phase 1~
Power supply frequency 50Hz
IP class IP44
Maximum electrical power consumption 55W
Electrical power consumption (standby) 2W
Gas category and supply pressure
Country Gas category Default setting After conversion to G25 After conversion to G31
Germany II2ELL3P G20 (20mbar) G25 (25mbar) G31 (28~50mbar)
Belgium
1
I2E(s)3Pc,
I3P
G20 (20mbar) G25 (25mbar) G31 (30mbar)
France II2Esi3P G20 (20mbar) G25 (25mbar) G31 (30mbar)
Italy II2H3P G20 (20mbar) — G31 (30mbar)
United Kingdom II2H3P G20 (20mbar) — G31 (30~37mbar)
Spain II2H3P G20 (20mbar) — G31 (30~37mbar)
Austria II2H3P G20 (20mbar) — G31 (30~50mbar)
Bulgaria II2H3P G20 (20mbar) — G31 (30mbar)
Czech Republic II2H3+,
II2H3P
G20 (20mbar) — G31 (37mbar)
Croatia II2H3P G20 (20mbar) — G31 (30mbar)
Hungary II2HS3P G25 (25mbar) — G31 (30mbar)
Slovakia II2H3P G20 (20mbar) — G31 (30~50mbar)
Slovenia II2H3P G20 (20mbar) — G31 (37mbar)
Portugal II2H3+ G20 (20mbar) — G31 (37mbar)
Greece II2H3+ G20 (20mbar) — G31 (37mbar)
Cyprus II2H3+ G20 (20mbar) — G31 (37mbar)
Poland II2H3P G20 (20mbar) — G31 (37mbar)
Ireland II2H3+ G20 (20mbar) — G31 (37mbar)
Turkey II2H3+ G20 (20mbar) — G31 (37mbar)
Switzerland II2H3+ G20 (20mbar) — G31 (37mbar)
Malta I3P — — G31 (30mbar)
Lithuania II2H3P G20 (20mbar) — G31 (30mbar)
Latvia II2H3P G20 (20mbar) — G31 (30mbar)
Denmark II2H3P G20 (20mbar) — G31 (30mbar)
Romania II2H3P G20 (20mbar) — G31 (30mbar)
(1)
Any modifications to the gas valve MUST be performed by a certified representative of the manufacturer. For more
information, contact your dealer.