AMST***U1400**
AIR HANDLERS INSTALLATION &
OPERATING INSTRUCTIONS
© 2021-2023 Daikin Comfort Technologies Manufacturing, L.P.
19001 Kermier Rd., Waller, TX 77484
www.goodmanmfg.com -or- www.amana-hac.com
P/N: IO-4004C Date: April 2023
RECOGNIZE THIS SYMBOL
AS A SAFETY PRECAUTION.
NOTE: SPECIFICATIONS AND PERFORMANCE DATA LISTED HEREIN
ARE SUBJECT TO CHANGE WITHOUT NOTICE
Contents
1 Important Safety Instructions .................................... 2
2 Shipping Inspection ................................................... 3
2.1 Parts ....................................................................... 3
2.2 Handling ................................................................. 3
2.3 Shipping Material Removal..................................... 3
2.3.1 Blower Support Bracket Removal ....................... 3
3 Codes & Regulations ................................................. 3
4 Replacement Parts ..................................................... 4
5 Pre-Installation Considerations ............................... 4
5.1 Preparation ............................................................. 4
5.2 System Matches ..................................................... 4
5.3 Interconnecting Tubing ........................................... 4
5.4 Clearances ............................................................. 4
5.5 Horizontal Applications ........................................... 4
5.6 Access .................................................................... 4
6 Installation Location ................................................... 4
 .................................................. 4
6.2 Horizontal Left Installation ...................................... 5
 5
6.4 Humid Environment Installations ............................ 6
6.4.1 All Installations – Humid Environments ............... 6
 6
6.4.1.3 Horizontal Installations – Humid Environments 6
7 Refrigerant Lines ........................................................ 7
7.1 Tubing Size ............................................................. 7
7.2 Tubing Preparation ................................................. 7
7.3 Tubing Connections ................................................ 7
7.4 Thermal Expansion Valve System Adjustment ....... 9
8 Condensate Drain Lines ........................................... 10
9 Ductwork .................................................................... 11
9.1 Return Ductwork .................................................... 11
10 Return Air Filters ..................................................... 11
11 Electric Heat ............................................................. 11
12 Electrical and Control Wiring ................................. 12
12.1 Building Electrical Service Inspection .................. 12
12.2 Wire Sizing .......................................................... 12
12.3 Maximum Overcurrent Protection (MOP) ............ 12
12.4 Electrical Connections – Supply Voltage ............. 13
12.4.1 Air Handler Only (Non-Heat Kit Models) ........... 13
12.4.2 Air Handler - Non-Circuit Breaker Heat Kits ..... 13

























WARNING
RECOGNIZE THIS SYMBOL
AS A SAFETY PRECAUTION

WARNING
Question and Answer IconNeed help?

Do you have a question about the Daikin AMST U1400 Series and is the answer not in the manual?

Daikin AMST U1400 Series Specifications

General IconGeneral
BrandDaikin
ModelAMST U1400 Series
CategoryAir Handlers
LanguageEnglish

Summary

Important Safety Instructions

Shipping Inspection and Handling

Parts, Handling, and Bracket Removal

Inspect parts, handle unit safely, and remove blower support bracket.

Codes, Regulations, and Parts Information

Pre-Installation Considerations

Preparation, System Matching, and Clearances

Read instructions, gather tools, ensure system matches, and maintain clearances.

Installation Location and Orientation

Orientation and Humid Environment Setup

Install in upflow, downflow, horizontal, and address humid environment needs.

Refrigerant Line Installation

Tubing and TXV Connections

Follow specs for tubing, prepare ends, braze connections, and adjust TXV.

Condensate Drain Lines

Ductwork, Air Filters, and Electric Heat

Ductwork and Filter Installation

Connect return ductwork and install air filters for proper airflow.

Electric Heat Installation

Install approved electric heat kits according to specifications.

Electrical and Control Wiring

Service Inspection, Wire Sizing, and Protection

Inspect supply, size wires, and install overcurrent protection.

Supply Voltage and Heat Kit Wiring

Connect supply voltage and wire different heat kit configurations.

Low Voltage Connections and Thermostats

Thermostat Wiring

Connect thermostat for single/multi-stage heating or heat pump.

Blower Speed Tap Adjustment

Speed Tap Selection (Taps 1-9)

Adjust blower speed by moving wires and jumpers.

Airflow Data Tables

Air Handler Low Voltage Connections

Wiring Diagrams

Cooling and Heat Pump Unit Wiring

Diagrams for cooling and heat pump units with optional heat kits.

Specific Model Wiring Diagrams

Diagrams for AMST**U1400**, AMST60DU1400**, and 3 Phase Heat Kits.

Routine Maintenance Recommendations

Filter and Coil Maintenance

Clean/replace filter monthly; flush coils with water; avoid chemicals.

Servicing Advice

Check thermostat, breakers, disconnects, and filters before calling a qualified servicer.