42
Submenu Item User Modifiable Options Comments
Cool Airflow (CL CFM) 18, 24, 30, 36, 42, 48, or 60,
default is 18
Selects the airflow for the non-
communicating compatible single stage
AC unit
Cool Airflow Trim (CL TRM) -10% to +10% in 2% increments,
default is 0%
Selects the airflow trim amount for the
non-communicating compatible single
stage AC unit
Cool Airflow Profile (CL PRFL) A, B, C, or D, default is A Selects the airflow profile for the non-
communicating compatible single stage
AC unit
Cool ON Delay (CL ON) 5, 10, 20, or 30 seconds, default
is 5 seconds
Selects the indoor blower ON delay for
the non-communicating compatible single
stage AC unit
Cool OFF Delay (CL OFF) 30, 60, 90, or 120 seconds,
default is 30 seconds
Selects the indoor blower OFF delay for
the non-communicating compatible single
stage AC unit
NON-COMM (APPLIES ONLY TO A COMMUNICATING COMPATIBLE FURNACE MATCHED
WITH A NON-COMMUNICATING COMPATIBLE SINGLE STAGE AIR CONDITIONER)