EasyManua.ls Logo

Daikin DM96VC - Page 42

Daikin DM96VC
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42
Submenu Item User Modifiable Options Comments
Cool Airflow (CL CFM) 18, 24, 30, 36, 42, 48, or 60,
default is 18
Selects the airflow for the non-
communicating compatible single stage
AC unit
Cool Airflow Trim (CL TRM) -10% to +10% in 2% increments,
default is 0%
Selects the airflow trim amount for the
non-communicating compatible single
stage AC unit
Cool Airflow Profile (CL PRFL) A, B, C, or D, default is A Selects the airflow profile for the non-
communicating compatible single stage
AC unit
Cool ON Delay (CL ON) 5, 10, 20, or 30 seconds, default
is 5 seconds
Selects the indoor blower ON delay for
the non-communicating compatible single
stage AC unit
Cool OFF Delay (CL OFF) 30, 60, 90, or 120 seconds,
default is 30 seconds
Selects the indoor blower OFF delay for
the non-communicating compatible single
stage AC unit
NON-COMM (APPLIES ONLY TO A COMMUNICATING COMPATIBLE FURNACE MATCHED
WITH A NON-COMMUNICATING COMPATIBLE SINGLE STAGE AIR CONDITIONER)