EasyManua.ls Logo

Daikin DV60FECD14 - User Manual

Daikin DV60FECD14
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Our continuing commitment to quality products may mean a change in specications without notice.
© 2015-2019
5151 San Felipe St., Suite 500, Houston, TX 77056
www.daikincomfort.com
DV**PEC / DV**FEC (EEV SERIES AIR HANDLERS)
IOD-4018J
11/2019
INSTALLATION INSTRUCTIONS
1 Important Safety Instructions ............................................................... 2
2 Shipping Inspection ...............................................................................3
2.1 Parts ........................................................................................................3
2.2 Handling ..................................................................................................3
3 Codes & Regulations ............................................................................. 3
4 Replacement Parts.................................................................................3
5 Pre-Installation Considerations ........................................................... 3
5.1 Preparation .............................................................................................. 3
5.2 System Matches ...................................................................................... 3
5.3 Interconnecting Tubing ............................................................................ 3
5.4 Clearances ..............................................................................................3
5.5 Horizontal Applications ............................................................................3
6 Installation Location ............................................................................. 4
6.1 Upow Installation ................................................................................... 4
6.2 Horizontal Left Installation ....................................................................... 4
6.3 Downow/Horizontal Right Installation .................................................... 4
7 Refrigerant Lines ................................................................................... 7
7.1 Tubing Size .............................................................................................. 7
7.2 Tubing Preparation .................................................................................. 7
7.3 Tubing Connections ................................................................................. 8
8 Condensate Drain Lines ........................................................................ 8
9 Ductwork.................................................................................................9
9.1 Return Ductwork ...................................................................................... 9
10 Return Air Filters ..................................................................................9
11 Electric Heat ......................................................................................... 9
12 Electrical and Control Wiring ............................................................ 11
12.1 Building Electrical Service Inspection .................................................. 11
12.2 Wire Sizing .......................................................................................... 11
12.3 Maximum Overcurrent Protection (MOP) ............................................ 11
12.4 Electrical Connections – Supply Voltage ............................................. 11
12.4.1 Air Handler Only (Non-Heat Kit Models) ........................................... 11
12.4.2 Air Handler - Non-Circuit Breaker Heat Kits ..................................... 11
12.4.3 Air Handler With Circuit Breaker Heat Kit ......................................... 11
13 Achieving 1.4% & 2% Low Leakage Rate ........................................ 12
14  Airow Trim ........................................................................................ 12
15 Miscellaneous Start-Up Checklist .................................................... 12
15.1 Auxiliary Alarm Switch .........................................................................13
15.2 Circulator Blower ................................................................................. 14
15.3 Motor Orientation ................................................................................. 14
15.4 Accessory Contacts ............................................................................. 14
16  Troubleshooting .................................................................................. 15
16.1 Electrostatic Discharge (ESD) Precautions ....................................... 15
16.2 Diagnostic Chart ................................................................................. 15
16.3 Fault Recall.........................................................................................15
17 Fully Communicating Daikin System ................................................ 16
17.1 Overview..............................................................................................16
17.2 Airow Consideration ...........................................................................16
17.3 Thermostat Wiring ...............................................................................16
17.3.1 Two-Wire Outdoor and Four-Wire Indoor Wiring ......................... 16
17.4 Network Troubleshooting ..................................................................... 16
17.5 System Troubleshooting ...................................................................... 17
Troubleshooting ........................................................................................ 18
Diagnostic Codes ......................................................................................21
Setting the mode display .......................................................................... 22
Wiring Diagram .......................................................................................... 24
Routine Maintenance ................................................................................ 25
NOTICE
If an “Ed” error is encountered
on startup, verify that the
electric heater DIP switches
have been set to the appropriate 
heater size. See Tables 9 and 10 
for the heater kit airow delivery
and DIP switch settings.
Only personnel that have been trained to install, adjust, service or
repair (hereinafter, “service”) the equipment specified in this manual
should service the equipment. The manufacturer will not be
responsible for any injury or property damage arising from improper
service or service procedures. If you service this unit, you assume
responsibility for any injury or property damage which may result. In
addition, in jurisdictions that require one or more licenses to service
the equipment specified in this manual, only licensed personnel
should service the equipment. Improper installation, adjustment,
servicing or repair of the equipment specified in this manual, or
attempting to install, adjust, service or repair the equipment specified
in this manual without proper training may result in product damage,
property damage, personal injury or death.
RECOGNIZE THIS  SYMBOL 
AS A SAFETY PRECAUTION.
Cancer and Reproductive Harm -
www.P65Warnings.ca.gov
PROP 65 WARNING
FOR CALIFORNIA CONSUMERS
0140M00517-A
Question and Answer IconNeed help?

Do you have a question about the Daikin DV60FECD14 and is the answer not in the manual?

Summary

Important Safety Instructions

Pre-Installation Considerations

System Compatibility Checks

Ensure system combination is manufacturer approved and AHRI listed.

Refrigerant Tubing Guidelines

Minimize refrigerant tubing length and allow for coil removal.

Installation Location

Refrigerant Lines

Condensate Drain Lines

Ductwork

Electric Heat

Electrical and Control Wiring

Electrical Service Inspection

Inspect single-phase supply voltage, ensure agreement with unit nameplate.

Supply Voltage Electrical Connections

Use copper conductors, follow wiring diagrams for connections.

Miscellaneous Start-Up Checklist

Troubleshooting

ESD Precautions for Servicing

Disconnect power, touch metal surface to discharge static before servicing.

Troubleshooting Diagnostic Chart

Refer to troubleshooting chart; 7-segment LED display shows fault codes.

Fault Recall Procedure

Use push-button to display last six faults; clear error history.

Fully Communicating Daikin System

Communicating System Overview

System with compatible air handler, AC/HP, and thermostat; two-way digital communication.

Communicating System Network Troubleshooting

Use onboard tools (LEDs, learn button) to troubleshoot network.

Communicating System Troubleshooting

Refer to outdoor unit manual for troubleshooting specific to communicating systems.

Mode Display Settings

Routine Maintenance Recommendations

Pre-Servicing Checks

Check thermostat, wait 15 mins, check breakers, disconnect switch, obstructions.

Summary

Important Safety Instructions

Pre-Installation Considerations

System Compatibility Checks

Ensure system combination is manufacturer approved and AHRI listed.

Refrigerant Tubing Guidelines

Minimize refrigerant tubing length and allow for coil removal.

Installation Location

Refrigerant Lines

Condensate Drain Lines

Ductwork

Electric Heat

Electrical and Control Wiring

Electrical Service Inspection

Inspect single-phase supply voltage, ensure agreement with unit nameplate.

Supply Voltage Electrical Connections

Use copper conductors, follow wiring diagrams for connections.

Miscellaneous Start-Up Checklist

Troubleshooting

ESD Precautions for Servicing

Disconnect power, touch metal surface to discharge static before servicing.

Troubleshooting Diagnostic Chart

Refer to troubleshooting chart; 7-segment LED display shows fault codes.

Fault Recall Procedure

Use push-button to display last six faults; clear error history.

Fully Communicating Daikin System

Communicating System Overview

System with compatible air handler, AC/HP, and thermostat; two-way digital communication.

Communicating System Network Troubleshooting

Use onboard tools (LEDs, learn button) to troubleshoot network.

Communicating System Troubleshooting

Refer to outdoor unit manual for troubleshooting specific to communicating systems.

Mode Display Settings

Routine Maintenance Recommendations

Pre-Servicing Checks

Check thermostat, wait 15 mins, check breakers, disconnect switch, obstructions.

Daikin DV60FECD14 Specifications

General IconGeneral
ModelDV60FECD14
Sound Pressure Level45 dB(A)
Cooling Capacity17.5 kW
Airflow3400 m³/h
RefrigerantR410A
Airflow Rate3400 m³/h
Cooling Capacity (kW)17.5

Related product manuals