INSTALLATION INSTRUCTIONS
HEAT PUMP
DZ17VSA HEAT PUMP
INSTALLATION & SERVICE REFERENCE
Index
Important Safety InStructIonS ............................................. 1
ShIppIng InSpectIon .............................................................. 2
codeS & regulatIonS .......................................................... 2
featureS.............................................................................. 2
acceSSorIeS ........................................................................ 2
Before InStallatIon .............................................................2
precautIonS for SelectIng a locatIon ................................. 3
precautIonS for InStallatIon ............................................... 3
InStallatIon clearanceS ......................................................4
cold clImate heat pump operatIon locatIon ...................... 5
rooftop InStallatIonS .........................................................5
electrIcal noISe ................................................................. 5
Safety conSIderatIonS......................................................... 6
meanIngS of SymBolS .......................................................... 6
refrIgerant lIneS ............................................................... 8
refrIgerant lIne connectIonS ........................................... 10
leak teStIng (nItrogen or nItrogen-traced) .................... 10
Stop ValVe operatIon method ........................................... 11
SyStem Start-up procedure .............................................. 11
Start-up procedure detaIl ................................................ 12
electrIcal connectIonS ....................................................12
Step 1. calculate refrIgerant charge BaSed on
lIne Set length .......................................................... 16
Step 2. connect heat pump to SyStem .............................. 18
Step 3. SyStem Start-up teSt ............................................ 18
addItIonal charge adjuStIng procedure .......................... 18
Step 4. adjuSt refrIgerant leVel ..................................... 18
Step 5. meaSure SuBcoolIng to VerIfy proper charge ..... 18
heat pump wIth outdoor temperature lockoutS ............... 19
wIrIng dIagram ................................................................ 20
teStIng capacItor reSIStance ............................................22
coolIng analySIS chart .................................................... 24
heatIng analySIS chart ..................................................... 25
trouBleShootIng ...............................................................26
SettIng the mode dISplay .................................................. 31
7-Segment dISplay ............................................................. 37
heat pump homeownerS routIne maIntenance
recommendatIonS ........................................................ 40
Start up checklISt ........................................................... 41
ctk04 addendum ............................................................... 43
Important Safety InStructIonS
The following symbols and labels are used throughout this
manual to indicate immediate or potential safety hazards. It is
the owner’s and installer’s responsibility to read and comply
with all safety information and instructions accompanying
these symbols. Failure to heed safety information increases
the risk of personal injury, property damage, and/or product
damage. Also see “Meanings of Symbols” on page 6.
WARNING
HIGH VOLTAGE !
dISconnect all power Before SerVIcIng.
multIple power SourceS may Be preSent. faIlure
to do So may cauSe property damage, perSonal
Injury or death.
WARNING
only perSonnel that haVe Been traIned to InStall, adjuSt, Ser-
VIce or repaIr (hereInafter, “SerVIce”) the equIpment SpecIfIed
In thIS manual Should SerVIce the equIpment. the manufacturer
wIll not Be reSponSIBle for any Injury or property damage arIS-
Ing from Improper SerVIce or SerVIce procedureS. If you SerVIce
thIS unIt, you aSSume reSponSIBIlIty for any Injury or property
damage whIch may reSult. In addItIon, In jurISdIctIonS that re-
quIre one or more lIcenSeS to SerVIce the equIpment SpecIfIed In
thIS manual, only lIcenSed perSonnel Should SerVIce the equIp-
ment. Improper InStallatIon, adjuStment, SerVIcIng or repaIr of
the equIpment SpecIfIed In thIS manual, or attemptIng to InStall,
adjuSt, SerVIce or repaIr the equIpment SpecIfIed In thIS manual
wIthout proper traInIng may reSult In product damage, property
damage, perSonal Injury or death.
prop 65 warnIng
for calIfornIa conSumerS
WARNING
-
www.P65Warnings.ca.gov
CAUTION
do not waSh the heat pump wIth exceSSIVe water. an electrIc
Shock or fIre could reSult.
English
Français
Español
Our continuing commitment to quality products may mean a change in specications without notice.
© 2013, 2017-2019
Daikin Texas Technology Park,19001 Kermier Road,Waller, TX, 77484, U.S.A.
www.daikincomfort.com
3P515859-3P

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin DZ17VSA241AA and is the answer not in the manual?

Daikin DZ17VSA241AA Specifications

General IconGeneral
Model NumberDZ17VSA241AA
CategoryHeat Pump
Cooling Capacity (BTU)24000
SEER Rating17
HSPF Rating9.5
Heating Capacity (BTU)24000
Voltage208/230
RefrigerantR-410A
Compressor TypeScroll
Phase1
Unit Weight (lbs)220

Summary

Important Safety Instructions

Before Installation

Precautions for Installation

Precautions for Selecting a Location

Installation Clearances

Cold Climate Heat Pump Operation Location

Safety Considerations

Refrigerant Lines

Refrigerant Line Connections

Leak Testing (Nitrogen or Nitrogen-Traced)

System Start-Up Procedure

Start-Up Procedure Detail

Electrical Connections

High Voltage Connections

Low Voltage Connections

Step 1. Calculate Refrigerant Charge Based on Line Set Length

Step 2. Connect Heat Pump to System

Step 3. System Start-Up Test

Additional Charge Adjusting Procedure

Step 4. Adjust Refrigerant Level

Step 5. Measure Subcooling to Verify Proper Charge

Heat Pump With Outdoor Temperature Lockouts

Wiring Diagram

Testing Capacitor Resistance

Cooling Analysis Chart

Heating Analysis Chart

Troubleshooting

Network Troubleshooting

Diagnosing communication issues between system components using LEDs and dipswitches.

Heat Pump Homeowner's Routine Maintenance Recommendations

Before Calling Your Servicer

Troubleshooting steps before contacting a service technician.

Start-Up Checklist For Unitary Inverter

Pre Start-Up

Checklist of tasks to perform before energizing the unit.

Start-Up

Fields for recording electrical, pressure, and temperature data during startup.

System Start-Up Test

Set Thermostat to Charge Mode

Adjust Refrigerant Level

Measure Subcooling to Verify Proper Charge

Procedure to measure subcooling for verifying correct refrigerant charge.

Heat Pump With Outdoor Temperature Lockouts

Explanation of how outdoor temperature lockouts affect heat pump operation.

Field Selectable Boost Mode

Field Selectable Defrost Heat Mode

Dehumidification

Night Mode

System Setup (Sys Setup1 and Sys Setup2)

Equipment Test (Equip Test)

Mandatory test to check equipment functionality and stop valve position.

Cool Set-up

Adjusting cooling performance variables like airflow and fan delays.

Cool Run Values

Adjusting maximum compressor RPS for cooling performance.

Heat Pump Advanced Feature Menu

Diagnostics

Lists submenu items for clearing faults and viewing fault history.

Status

Lists submenu items for monitoring system status and operational data.

Cool Setup